Author: Kishi, D.
Paper Title Page
MOPB042 The TRIUMF/VECC Injector Cryomodule Performance 144
 
  • Y. Ma, K. Fong, T. Junginger, D. Kishi, A.N. Koveshnikov, R.E. Laxdal, N. Muller, R.R. Nagimov, D.W. Storey, E. Thoeng, Z.Y. Yao, V. Zvyagintsev
    TRIUMF, Vancouver, Canada
  • U. Bhunia, A. Chakrabarti, S. Dechoudhury, V. Naik
    VECC, Kolkata, India
 
  The collaboration on superconducting electron Linac for rare ion beam facilities ARIEL (Advanced Rare Iso-topE Laboratory) [1-4] and ANURIB [5] (Advanced Na-tional facility for Unstable and Rare Isotope Beams) has resulted in production of a superconducting Injector Cryomodule (VECC ICM) at TRIUMF for VECC. The cryomodule design utilizes a unique box cryomodule with a top-loading cold mass. The hermetic unit consists of a niobium cavity which operating at 1.3GHz and connected with two symmetrically opposed couplers which can deliver 100kW RF power to the beam. Liquid helium supplied at 4.4 K is converted to superfluid helium-II through a cryogenic insert on board which includes 4 K phase separator, 4K/2K heat exchanger and Joule-Thompson valve. In 2016, the VECC ICM has been tested at TRIUMF and demonstrated 10.5 MeV acceleration. A summary of the VECC ICM commissioning are presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-SRF2017-MOPB042  