Paper |
Title |
Page |
THYA06 |
Long-term Operation Experience with Beams in Compact ERL Cryomodules |
736 |
|
- K. Umemori, M. Egi, K. Enami, T. Furuya, Y. Honda, E. Kako, T. Konomi, H. Sakai
KEK, Ibaraki, Japan
- T. Okada
Sokendai, Ibaraki, Japan
- M. Sawamura
QST, Tokai, Japan
|
|
|
Compact ERL (cERL) was constructed at KEK as a prototype for 3GeV ERL light source. It consists of two types of SRF cavities. Three injector 2-cell SRF cavities and two main linac 9-cell SRF cavities. The beam operation started at 2013, with 100 nA (CW). Beam current increased step by step and currently reached to 1 mA (CW). Energy recovery has successfully achieved. Performance of the SRF cavities through long term beam operation has been investigated. With the beam induced HOMs, the beam position and the beam timing were studied. cERL has suffered from heavy field emissions in operation. Field emissions of the main linac cavity started just after module assembly work, and during beam operation, performances of both the main linac and the injector SRF cavities sometimes degraded. One reason of degradation was discharges occurred at beamline components due to charge up of electrons. Pulse aging technique helped to recover SRF performances. In this presentation, details of SRF beam operation, degradation, applied recovery methods are described.
|
|
|
Slides THYA06 [4.973 MB]
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-SRF2017-THYA06
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|