Paper |
Title |
Other Keywords |
Page |
TUPB016 |
High-Fidelity Modeling and Transmission Optimization for the Beamline of HUST-PTF |
proton, simulation, vacuum, coupling |
117 |
|
- Y.C. Chen, C.L. Liu, X. Liu, B. Qin, W. Wang
HUST, Wuhan, People’s Republic of China
|
|
|
A superconducting cyclotron-based proton therapy facility is under construction at Huazhong University of Science and Technology (HUST-PTF). In previous works, the vacuum chamber’s shape and the tail effect of the energy spectrum are not considered when calculating the transmission efficiency of the beamline. This study proposes a high-fidelity modeling and optimization method for the HUST-PTF beamline based on Monte Carlo simulation using BDSIM. The modeling procedure of the beamline based on BDSIM is briefly introduced. Then verification of the optical parameters are performed on the gantry sections, and the transmission efficiency of the gantry is optimized by analyzing the unexpected beam loss. After optimization, the transmission efficiency at each energy setting point is calculated. The simulation results show that (1) the proposed optimization method improves the gantry’s transmission efficiency from 92.4% to 95.6%; (2) the transmission efficiency calculated by high-fidelity modeling is more accurate than previous simulations because the beam-matter interaction and practical vacuum chamber geometry are considered.
|
|
DOI • |
reference for this paper
※ doi:10.18429/JACoW-SAP2023-TUPB016
|
|
About • |
Received ※ 29 June 2023 — Revised ※ 09 July 2023 — Accepted ※ 11 July 2023 — Issued ※ 09 February 2024 |
Cite • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|