Author: Chen, H.B.
Paper Title Page
MOPH24 Electromagnetic and Mechanical Design of High Gradient S-band Accelerating Structure in TTX 83
 
  • D.Z. Cao, H.B. Chen, Y. C. Du, W. Gai, W.-H. Huang, J. Shi, C.-X. Tang, H. Zha
    TUB, Beijing, People's Republic of China
 
  Thomson scattering x-ray source is an essential scien-tific platform and research tool in x-ray imaging technol-ogy for various fields. Upgrading plan that replacing the 3-meter S-band old linac with shorter high-gradient struc-ture in Tsinghua Thomson scattering X-ray source (TTX) is undergoing so far, aiming to enhance accelerating gradient from 15MV/m to 30MV/m. Detailed parameters of couplers and electromagnetic simulation results of whole acceleration structure are presented in this paper. Finally, mechanical structure and further upgrading re-search on energy with X-band structures are also discussed.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-SAP2017-MOPH24  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WECH2 Overall Design and Progress of XiPAF Project 183
 
  • S.X. Zheng, C.B. Bi, H.B. Chen, C. Cheng, C.T. Du, T.B. Du, X. Guan, Q.K. Guo, W.-H. Huang, G.R. Li, P.F. Ma, K.D. Man, C.-X. Tang, R. Tang, D. Wang, W. Wang, X.W. Wang, Q.Z. Xing, Y. Yang, H.J. Yao, H.J. Zeng, H.Y. Zhang, Q. Zhang
    TUB, Beijing, People's Republic of China
  • W. Chen
    NINT, Xi'an, People's Republic of China
  • Y.M. Fu, M.T. Qiu, E.Y. Qu, B.C. Wang, D. Wang, M.C. Wang, Y.P. Wang, Z.M. Wang, C.Y. Wei, Y.H. Yan, H.Z. Zhang, C. Zhao, W.L. Liu
    State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Shannxi, People's Republic of China
  • W.Q. Guan, Y. He, J. Li
    NUCTECH, Beijing, People's Republic of China
 
  Xi an Proton Application Facility (XiPAF) which consists of one 230 MeV proton accelerator and irradiation stations, will be constructed in Xi an city, Shaanxi, China. The facility is composed of a 230 MeV synchrotron, a 7 MeV H linac injector and two experimental stations. It can provide a flux of 105~108 p/cm2/s with the uniformity of better than 90% on the 10 cm×10 cm sample. The overall design of XiPAF accelerator is presented in this paper. And the progress of project is reported also.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-SAP2017-WECH2  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)