JACoW logo

Journals of Accelerator Conferences Website (JACoW)

JACoW is a publisher in Geneva, Switzerland that publishes the proceedings of accelerator conferences held around the world by an international collaboration of editors.


RIS citation export for FRB03: Upgrated the Extraction Device of Focused Electron Beam Into the Atmosphere

TY  - CONF
AU  - Domarov, E.V.
AU  - Chakin, I.
AU  - Cherepkov, V.G.
AU  - Fadeev, S.
AU  - Golkovsky, M.
AU  - Golubenko, Yu.I.
AU  - Korchagin, A.I.
AU  - Kuksanov, N.K.
AU  - Lavrukhin, A.
AU  - Nemytov, P.I.
AU  - Salimov, R.A.
AU  - Semenov, A.V.
ED  - Kuzin, Maksim V.
ED  - Schaa, Volker RW
TI  - Upgrated the Extraction Device of Focused Electron Beam Into the Atmosphere
J2  - Proc. of RuPAC2021, Alushta, Crimea, 27 September-01 October 2021
CY  - Alushta, Crimea
T2  - Russian Particle Accelerator Conference
T3  - 27
LA  - english
AB  - For over 30 years, an extraction device has been successfully working in BINP at the ELV-6 accelerator to extract a focused beam of electrons into the atmosphere. The accelerating tube with permanent magnetic lenses was used in this installation. The design of these accelerator tubes with magnetic lenses is rather complicated. Recently, simpler design and high reliability accelerating tubes with big aperture is operating in ELV accelerators. For this reason, the problem number one at present is to develop the extraction device, capable of reliably working with serial accelerator tubes, of the ELV accelerator with power up to100 kW. The lens L1 is located directly at the lower end of the accelerating tube. Passing the lens L1, the beam is focused near the diaphragm D6 and increases to a diameter of 10 mm in the diaphragm D5. For passing the beam along the axis of the diaphragms, there are corrections coils C1 C2 C3. The diameter of diaphragm hole D1 is the most critical, because it determines the flow of gas that should be pumped out in the following steps of the vacuum system. Measurements of the parameters of a high-power electron beam were carried out up to a power of 100 kW. As a result of the made experiments the minimum diameter of the beam at the exit from the extractions device has been 2 mm at the energy of 1,4 MeV and the beam current of 60 mA.
PB  - JACoW Publishing
CP  - Geneva, Switzerland
SP  - 114
EP  - 116
KW  - electron
KW  - focusing
KW  - extraction
KW  - cathode
KW  - permanent-magnet
DA  - 2021/10
PY  - 2021
SN  - 2673-5539
SN  - 978-3-95450-240-0
DO  - doi:10.18429/JACoW-RuPAC2021-FRB03
UR  - https://jacow.org/rupac2021/papers/frb03.pdf
ER  -