JACoW logo

Joint Accelerator Conferences Website

The Joint Accelerator Conferences Website (JACoW) is an international collaboration that publishes the proceedings of accelerator conferences held around the world.


RIS citation export for WEPSB20: Thyratron Operating Pressure Monitoring Systems

TY - CONF
AU - Bochkov, Bochkov, V.D.
AU - Bochkov, D.V.
AU - Dyagilev, V.M.
AU - Salynov, I.A.
AU - Ushich, V.G.
AU - Vasiliev, I.V.
ED - Kuzin, Maksim V.
ED - Schaa, Volker RW
TI - Thyratron Operating Pressure Monitoring Systems
J2 - Proc. of RUPAC2018, Protvino, Russia, 01-05 October 2018
C1 - Protvino, Russia
T2 - Russian Particle Accelerator Conference
T3 - 26
LA - english
AB - The known statistics data amassed for power thyratrons in accelerators show remarkable potential of the plasma switches in terms of lifetime covering the range from several thousand up to 120 thousand hours total*,**. The gap in the lifetime can be reduced both by measures of improvements in technology and implementation of thyratron parameters monitoring systems. It is known that the thyratron lifetime mainly depends on continuity of gas pressure and cathode emission. In this paper the initial research on some effective means of gas pressure monitoring automation is described. The pressure monitoring in thyratrons TGI-, TPI- and TDI-types is possible in absence of anode voltage either by registration of triggering parameters in a new igniter design or by a special built-in high-temperature pressure gauge.
PB - JACoW Publishing
CP - Geneva, Switzerland
SP - 327
EP - 329
KW - cathode
KW - monitoring
KW - operation
KW - electron
KW - plasma
DA - 2018/11
PY - 2018
SN - 978-3-95450-197-7
DO - 10.18429/JACoW-RUPAC2018-WEPSB20
UR - http://jacow.org/rupac2018/papers/wepsb20.pdf
ER -