TUPSA17 Axial Injection to a Compact Cyclotron with High Magnetic Field 75
 
  • V.L. Smirnov, S.B. Vorozhtsov
    JINR/DLNP, Dubna, Moscow region, Russia
 
  One of advantages of a compact cyclotron over other type accelerators is a small size mainly defined by the facility’s bending magnetic field. In such cyclotrons an application of an external injection is required in some cases. But for high magnetic field of the cyclotrons (over 4-5 T) there appears a severe problem to make the 1st turns in the machine with external injection of accelerated particles. This paper describes a proposal of a new central region structure of a compact cyclotron that permits one to successfully solve the problem of the axial injection into such a facility using a spiral inflector.