Paper | Title | Page |
---|---|---|
WEPSB15 | The Utilization of Standard DC Accelerator ELV for The Tomography | 186 |
|
||
ELV accelerators have been developed at the Institute of Nuclear Physics, Siberian Branch of the Russian Academy of Sciences and occupy a special place in the spectrum of the equipment produced by the Institute. These machines are widely used for radiation modification of polymers and worked well in a variety of processes in many countries of the Eurasian continent. Using serial ELV accelerators for industrial tomography opens up new possibilities for industrial technologies. This increases the requirements on the stability parameters of the injected electron beam. The article formulates the requirements for electron accelerator ELV for tomographic studies, pulsation energy and beam current. Described Schottky effect affects to the shape and size of the ripple current, and the method for increasing the stability of the beam parameters. These machines are unified with conventional accelerators ELV and expand the scope of their utilization. | ||