Paper | Title | Page |
---|---|---|
THPD40 | Instrumentation Architecture for ITER Diagnostic Neutral Beam Power Supply System | 214 |
|
||
A Neutral Beam Injection system is used for either heating or diagnostics of the plasma in a tokamak. The Diagnostics Neutral Beam system [1] for ITER based on acceleration of negative ions; injects a neutral (Ho) beam at 100KeV with specified modulation into the plasma for charge exchange recombination spectroscopy. DNBPS system consists of HVPS, HCPS and RF Sources. The system operates in a given operating sequence; very high electromagnetic transients are intrinsically generated during operation. Instrumentation is to be provided to operate the DNBPS system remotely with required control and protection. The operation is to be synchronized with ITER operation as directed by CODAC. Instrumentation functionality includes
[1] Lennart Svensson et.al, "Instrumentation and diagnostics for the ITER Neutral Beam System", Fusion Engineering and Design 86 (2011) |
||
![]() |
Poster THPD40 [1.032 MB] | |