A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

White, M.

Paper Title Page
TUPMN089 Configuration, Optics, and Performance of a 7-GeV Energy Recovery Linac Upgrade for the Advanced Photon Source 1121
 
  • M. Borland, G. Decker, A. Nassiri, M. White
    ANL, Argonne, Illinois
 
  Funding: Work supported by the U. S. Department of Energy, Office of Science, Basic Energy Sciences, under Contract No. DE-AC02-06CH11357.

The Advanced Photon Source (APS) is a 7-GeV storage ring light source that has been in operation for over a decade. In order to make revolutionary improvements in the performance of the existing APS ring, we are exploring the addition of a 7-GeV energy recovery linac (ERL) to the APS complex. In this paper, we show the possible configuration of such a system, taking into account details of the APS site and the requirement that stored beam capability be preserved. We exhibit a possible configuration for the single-pass, 7-GeV linac. We discuss optical solutions for transport from 10 MeV to 7 GeV and back, including a large turn-around arc that would support 48 additional user beamlines. Tracking results are shown that include incoherent and coherent synchrotron radiation, resulting in predictions of the beamline performance.

 
TUPMN100 LCLS Undulator Production 1148
 
  • E. Trakhtenberg, T. Barsz, P. K. Den Hartog, G. S. Lawrence, E. R. Moog, S. Sasaki, I. Vasserman, M. White
    ANL, Argonne, Illinois
  • T. Becker, S. Dufresne, W. Kummerle, R. Schuermann
    Metalex Manufacturing, Cincinnati, Ohio
  • G. Goldfarb, N. Lagonsky, S. Lagonsky, S. Sorsher
    Hi-Tech Manufacturing, Schiller Park, Illinois
 
  Funding: Work supported by the U. S. Dept. of Energy, under contract numbers DE-AC02-06CH11357 and DE AC03-76SF00515.

Design and construction of the undulators for the Linac Coherent Light Source (LCLS) is the responsibility of Argonne National Laboratory. A prototype undulator* was constructed in-house and was extensively tested. The device was tunable to well within the LCLS requirements and was stable over a period of several years. Experience constructing the prototype undulator led us to conclude that with appropriate engineering design and detailed assembly procedures, precision undulators can be constructed by qualified vendors without previous undulator-construction experience. Our detailed technological knowledge and experience were transferred to the successful bidders who have produced outstanding undulators. Our production concept for the 40 3.4 m long, fixed-gap, planar-hybrid undulators with a 30 mm period is presented. Manufacturing, quality assurance, and acceptance testing details are also presented.

*LCLS Prototype Undulator Report, Argonne National Laboratory Report ANL/APS/TB-48, January 2004, R. Dejus, Editor.