A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Wagner, J.

Paper Title Page
THPAS039 Status Report on the NSCL RF Fragment Separator 3585
 
  • M. Doleans, V. Andreev, B. Arend, D. Bazin, A. Becerril Reyes, R. Fontus, P. Glennon, D. Gorelov, P. F. Mantica, J. Ottarson, H. Schatz, B. Sherrill, J. Stoker, O. Tarasov, J. J. Vincent, J. Wagner, X. Wu, A. Zeller
    NSCL, East Lansing, Michigan
 
  The RF Fragment Separator (RFFS) proposed in* is now under construction and should be operational by May 2007. The RFFS is an additional purification system for secondary beams at the National Superconducting Cyclotron Laboratory after the existing A1900 fragment separator and will primarily be used to purify beams of rare neutron deficient isotopes. The RFFS uses a transverse electric field of an rf kicker to separate unwanted particles from the desired ion beam, a pi/2 phase advance cell to rotate the beam in phase space before the beam reaches a collimating aperture for purification and a final pi phase advance cell to transport the desired beam to the experiment. The final design for the rf kicker and the focusing system is presented and a status report on the building and commissioning effort is given.

* D. Gorelov, V. Andreev, D. Bazin, M. Doleans, T. Grimm, F. Marti, J. Vincent and X. Wu, "RF-Kicker System for Secondary Beams at NSCL/MSU" PAC2005, Knoxville, Tennessee, 16th-20th, May 2005