A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Shelley, F. E.

Paper Title Page
FRPMS051 Proposed Beam Diagnostics Instrumentation for the LANSCE Refurbishment Project 4099
 
  • J. D. Gilpatrick, B. Blind, M. J. Borden, J. L. Erickson, M. S. Gulley, S. S. Kurennoy, R. C. McCrady, J. F. O'Hara, M. A. Oothoudt, C. Pillai, J. F. Power, L. Rybarcyk, F. E. Shelley
    LANL, Los Alamos, New Mexico
 
  Funding: *Work supported by the U. S. Department of Energy.

Presently, the Los Alamos National Laboratory is in the process of planning a refurbishment of various sub-systems within its Los Alamos Neutron Science Center accelerator facility. A part of this LANSCE facility refurbishment will include some replacement of and improvement to existing older beam diagnostics instrumentation. While plans are still being discussed, some instrumentation that is under improvement or replacement consideration are beam phase and position measurements within the 805-MHz side-coupled cavity linac, slower wire profile measurements, typically known as wire scanners, and possibly additional installation of fast ionization-chamber loss monitors. This paper will briefly describe the requirements for these beam measurements, what we have done thus far to answer these requirements, and some of the technical issues related to the implementation of these instrumentation.