FRPMN005 Design of Button Beam Position Monitor for the Brazilian Synchrotron Light Source 3871
 
  • S. R. Marques, O. R. Bagnato, R. H.A. Farias, M. J. Ferreira, J. B. Gonzalez, C. Rodrigues, P. F. Tavares
    LNLS, Campinas
 
  We present the electric and mechanical design of a button beam position monitor (BPM) recently developed and installed in the UVX electron storage ring at the Brazilian Synchrotron Light Laboratory (LNLS). The first commissioning results will also be presented. This development started when we observed strong correlation between false stripline BPM readings and the external temperature of this BPM. Simulations indicate that the temperature gradient in the BPM body can cause deformations that could explain the false readings in some BPMs. The small dimension of the button compared to the stripline and the better thermal isolation between the button and the BPM body should contribute to minimize this problem.