TUPAS068 A Transverse Beam Instability in the PEP-II HER Induced by Discharges in the Vacuum System 1811
 
  • U. Wienands, W. S. Colocho, S. DeBarger, F.-J. Decker, S. Ecklund, A. S. Fisher, J. D. Fox, A. Kulikov, A. Novokhatski, M. Stanek, M. K. Sullivan, W. Wittmer, D. Wright, G. Yocky
    SLAC, Menlo Park, California
 
  Funding: Work supported by US Dept. of Energy

During Run 5, PEP-II has been plagued by beam instabilities causing beam aborts due to radiation in the BaBar detector or due to fast beam loss triggering the dI/dt interlock. The latest of such instabilities occurred in the High Energy Ring (HER), severely curtailing the maximum beam current achievable during physics running. Techniques used in tracking down this instability included fast monitoring of background radiation, temperatures and vacuum pressure. In this way, the origin of the instability was localized and inspection of the vacuum system revealed several damaged bellows shields. Replacing these units significantly reduced the incident rate but did not eliminate it fully. After the end of the run, a number of damaged rf seals were found, possibly having caused the remaining incidents of instability. In this paper we will outline the steps taken to diagnose and remedy the issue and also compare the different signatures of vacuum-induced instabilities we have seen in both rings of PEP-II during the run.