A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Kristensen, J.

Paper Title Page
TUPMN007 Final Commissioning Results from the Injection System for the Australian Synchrotron Project 926
 
  • S. V. Weber, F. Bødker, H. Bach, N. Hauge, J. Kristensen, L. K. Kruse, S. P. M?ller, S. M. Madsen
    Danfysik A/S, Jyllinge
  • M. J. Boland, R. T. Dowd, G. LeBlanc, M. J. Spencer, Y. E. Tan
    ASP, Clayton, Victoria
  • N. H. Hertel, J. S. Nielsen
    ISA, Aarhus
 
  Danfysik has delivered a full-energy turn-key injection system for the Australian Synchrotron. The system consists of a 100 MeV linac, a low-energy transfer beamline, a 130 m circumference 3-GeV booster, and a high energy transfer beamline. The booster lattice was designed to have many cells with combined-function magnets (dipole, quadrupole and sextupole fields) in order to reach a very small emittance. The injection system has been commissioned and found to deliver a beam with an emittance of less than 30 nm, and currents in single- and multi-bunch mode in excess of 0.5 and 5 mA, respectively, fulfilling the contractual performance specifications. The repetition frequency is 1 Hz. Results from the commissioning of the system will be presented.