Paper | Title | Page |
---|---|---|
THIBKI04 | Developments of Long-pulse Klystron Modulator for KEK Super-conducting RF Test Facility | 2691 |
|
||
NICHICON (KUSATSU) CORPORATION and KEK have developed a novel long-pulse klystron modulator for both of single-beam tube(136kVp*100A) and multi-beam tube(120kVp*140A). The main features are; - crowberless system with optimized IGBT snubber circuit, - compact and highly reliable Self-Healing capacitors, - HV & LV twin pulse transformers of laminated steel core for reduced tank volume. Detailed configuration and test results to be presented. | ||
|
Slides |