MOPAN004 Commissioning of the LNLS Elliptically Polarizing Undulator 149
 
  • P. F. Tavares, N. P. Abreu, J. F. Citadini, R. H.A. Farias, M. J. Ferreira, J. G.R. S. Franco, L. C. Jahnel, L. Liu, A. F.A. G. Moreira, X. R. Resende, G. Tosin
    LNLS, Campinas
 
  We present the results of the commissioning of the first Elliptically Polarizing Undulator to be installed at the 1.37 GeV electron storage ring of the Brazilian Synchrotron Light Source. The undulator is designed to provide UV and soft X-ray photons from 100 eV up to 1 keV with full polarization control. It uses the APPLE II design with 50 mm period and 22 mm gap and allows for both parallel and anti-parallel longitudinal motion of its magnet cassettes. We present the commissioning results including the measured orbit and tune perturbations as well as the non-linear effects of the undulator fields on the stored beam and the corresponding impact on the beam lifetime.  
FRPMN005 Design of Button Beam Position Monitor for the Brazilian Synchrotron Light Source 3871
 
  • S. R. Marques, O. R. Bagnato, R. H.A. Farias, M. J. Ferreira, J. B. Gonzalez, C. Rodrigues, P. F. Tavares
    LNLS, Campinas
 
  We present the electric and mechanical design of a button beam position monitor (BPM) recently developed and installed in the UVX electron storage ring at the Brazilian Synchrotron Light Laboratory (LNLS). The first commissioning results will also be presented. This development started when we observed strong correlation between false stripline BPM readings and the external temperature of this BPM. Simulations indicate that the temperature gradient in the BPM body can cause deformations that could explain the false readings in some BPMs. The small dimension of the button compared to the stripline and the better thermal isolation between the button and the BPM body should contribute to minimize this problem.