A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Palmer, D.T.

Paper Title Page
TPAE028 Beam Dynamics Studies for a Laser Acceleration Experiment 2024
 
  • J.E. Spencer, E.R. Colby, R.J. Noble, D.T. Palmer, R. Siemann
    SLAC, Menlo Park, California
 
  Funding: Support of this work was under U.S. Dept. of Energy contract DE-AC02-76SF00515.

The NLC Test Accelerator at SLAC was built to address various beam dynamics issues for the Next Linear Collider. An S-Band RF gun, originally proposed for the NLCTA, is being installed together with a large-angle extraction line at 60 MeV. This is followed by a matching section, final focus and buncher for the laser acceleration experiment, E163. The laser-electron interaction area is followed by a broad range, high resolution spectrometer (HES) for electron bunch analysis. The RF gun is discussed in another paper. We discuss only the beam dynamics and high resolution analysis system at 6 MeV based on using Parmela and high-order Transport for bunch charges from 50 pC to 1 nC. Beyond the diagnostics, this system uses the emittance compensating solenoids and a low energy, high resolution spectrometer (LES) to help tune for best operating point and match to the linac. Optical symmetries in the design of the 25.5° extraction line provide 1:1 phase space transfer without linear dispersion or use of sextupoles for a large, 6D phase space volume and range of input conditions. Tolerances and tuning sensitivities (knobs) for certain parts of the system are discussed.

 
TPPE040 RF and Magnetic Measurements on the SPARC Photoinjector and Solenoid at UCLA 2624
 
  • J.B. Rosenzweig, A.M. Cook, M.P. Dunning, P. Frigola, G. Travish
    UCLA, Los Angeles, California
  • D.T. Palmer
    SLAC, Menlo Park, California
  • C. Sanelli, F. Tazzioli
    INFN/LNF, Frascati (Roma)
 
  Funding: This work is supported by U.S. Dept. of Energy grant DE-FG03-92ER40693.

The rf photocathode gun and the solenoid for the SPARC project at INFN-LNF (Frascati) have been fabricated and undergone initial testing at UCLA. The advanced aspects of the design of these devices are detailed. Final diagnosis of the tuning of the RF gun performance, including operating mode frequency and field balance, is described. The emittance compensating solenoid magnet, which is designed to be tuned in longitudinal position by differential excitation of the coils, has been measured using Hall probe scans for field profiling, and pulsed wire methods to determine the field center.

 
TPPE057 An Experimental Study of the Quantum Efficiency and Topology of Copper Photocathode Due to Plasma Cleaning and Etching
 
  • D.T. Palmer, F. King, R.E. Kirby
    SLAC, Menlo Park, California
 
  We have developed an experimental research program to the study of the photoemission properties of copper photocathodes as a function of various plasma cleaning/etching parameters. The quantum efficiency, QE, and topology, Ra and Rpp, of Copper Photocathodes, , will be monitored while undergoing plasma cleaning/etching process. We will monitor the QE as a function of time for the various test coupons while we optimize the various plasma processing parameters. In addition, surface topology, will be studied to determine the suitability of the cleaning/etching process to produce an acceptable photoemitter. We propose to use two metrics in the evaluation of the plasma cleaning process as an acceptable cleaning method for metallic photocathodes, Quantum Efficiency versus Wavelength and Surface roughness: Ra and Rpp represent the Average Roughness and Peak to Peak Roughness parameters, respectively.  
RPPT013 Status of the SPARC Project 1327
 
  • L. Serafini, F. Alessandria, A. Bacci, S. Cialdi, C. De Martinis, D. Giove, M. Mauri, M. Rome, L. Serafini
    INFN-Milano, Milano
  • D. Alesini, M. Bellaveglia, S. Bertolucci, M.E. Biagini, R. Boni, M. Boscolo, M. Castellano, A. Clozza, G. Di Pirro, A. Drago, A. Esposito, M. Ferrario, L. Ficcadenti, D. Filippetto, V. Fusco, A. Gallo, G. Gatti, A. Ghigo, S. Guiducci, M. Incurvati, C. Ligi, F. Marcellini, M.  Migliorati, A. Mostacci, L. Palumbo, L. Pellegrino, M.A. Preger, R. Ricci, C. Sanelli, M. Serio, F. Sgamma, B. Spataro, A. Stecchi, A. Stella, F. Tazzioli, C. Vaccarezza, M. Vescovi, C. Vicario
    INFN/LNF, Frascati (Roma)
  • I. Boscolo, C. Maroli, V. Petrillo
    Universita' degli Studi di Milano, MILANO
  • F. Broggi
    INFN/LASA, Segrate (MI)
  • L. Catani, E. Chiadroni, A. Cianchi, E. Gabrielli, S. Tazzari
    INFN-Roma II, Roma
  • F. Ciocci, G. Dattoli, A. Dipace, A. Doria, F. Flora, G.P. Gallerano, L. Giannessi, E. Giovenale, G. Messina, P.L. Ottaviani, S. Pagnutti, G. Parisi, L. Picardi, M. Quattromini, A. Renieri, G. Ronci, C. Ronsivalle, M. Rosetti, E. Sabia, M. Sassi, A. Torre, A. Zucchini
    ENEA C.R. Frascati, Frascati (Roma)
  • D. Dowell, P. Emma, C. Limborg-Deprey, D.T. Palmer
    SLAC, Menlo Park, California
  • D. Levi, M. Mattioli, G. Medici, P. Musumeci, D. Pelliccia
    Università di Roma I La Sapienza, Roma
  • M. Nisoli, S. Stagira, S. de Silvestri
    Politecnico/Milano, Milano
  • M. Petrarca
    INFN-Roma, Roma
  • J.B. Rosenzweig
    UCLA, Los Angeles, California
 
  The SPARC project has entered its installation phase at INFN-LNF: its main goal is the promotion of an R&D activity oriented to the development of a high brightness photoinjector to drive SASE-FEL experiments. The design of the 150 MeV photoinjector has been completed and the construction of its main components is in progress, as well as the design of the 12 m undulator. In this paper we will report on the installation and test of some major components, like the Ti:Sa laser system to drive the photo-cathode, the RF gun, the RF power system, as well as some test results on the RF deflector and 4th harmonic X-band cavity prototypes. Advancements in the control and beam diagnostics systems will also be reported, in particular on the emittance-meter device for beam emittance measurements in the drift space downstream the RF gun. Recent results on laser pulse shaping, obtained with two alternative techniques (DAZZLER and Liquid Crystal Mask), show the feasibility of producing 10 ps flat-top laser pulses in the UV with rise time below 1 ps, as needed to maximize the achievable beam brightness. First FEL experiments have been proposed, using SASE, seeding and non-linear resonant harmonics: these will be briefly described.