A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Hanna, B.M.

Paper Title Page
RPPE051 NEG Pumping Strip Inside Tevatron B2 Magnets 3144
 
  • A.Z. Chen, T. G. Anderson, B.M. Hanna
    Fermilab, Batavia, Illinois
 
  Funding: DOE

NEG pumping strips were installed inside four Tevatron B2 Magnets in order to improve the vacuum environment in B2 magnets that have embedded unbakable vacuum chamber. The prelimary results shown the total presure in that region was significant reduced. Complelte testing and opertation results will be available soon.