FPAE051 Performance of a CW RFQ Injector for the IUCF Cyclotron 3179
 
  • V.P. Derenchuk, V. Anferov, G.W. East, D. Friesel, W.P. Jones
    IUCF, Bloomington, Indiana
  • R.W. Hamm
    AccSys, Pleasanton, California
  • J.W.  Staples
    LBNL, Berkeley, California
 
  Funding: The State of Indiana, Indiana University, and the DOE (Grant No DE-FG-02000ER62966) supported this work.

A 750 keV RFQ proton pre-injector was installed in place of a 600 keV Cockroft-Walton high voltage terminal for the IUCF k220 Cyclotron.* The pre-injector consists of a 20 keV microwave ion source and LEBT, a unique design 750 keV CW RFQ, and a short transfer beam line to the k15 injector cyclotron center region.** This pre-injector system was installed and commissioned in June of 2003 and is now in routine service as the sole injection system to the cyclotrons. This contribution will discuss the performance of the CW RFQ pre-injector and the transmission properties of the beam through the cyclotrons.

*D.L.Friesel, et al., App. of Acc. in Res. and Ind., eds. J.L. Duggan and I.L. Morgan, Denton, 651(2000). **V.P. Derenchuk, et al., 2003 Particle Accelerator Conference, Portland, OR, (2003), edited by A. Jackson and E. Lee.