Keyword: electronics
Paper Title Other Keywords Page
THXBA4 Update on BPM Signal Processing Circuitry Development at AWA detector, electron, controls, pick-up 919
 
  • W. Liu, M.E. Conde, D.S. Doran, G. Ha, J.G. Power, J.H. Shao, C. Whiteford, E.E. Wisniewski
    ANL, Lemont, Illinois, USA
  • C. Jing
    Euclid Beamlabs LLC, Bolingbrook, USA
 
  Funding: The US Department of Energy, Office of Science
Beam position monitor (BPM) is widely used in accelerator facilities worldwide. It is a device which is capable of providing, non-destructively, accurate beam centroid and charge information of a passing charged beam. A typical BPM system contains customized hardware and specialized processing electronics. The cost is often too high for small facilities to afford them. As a small facility, Argonne Wakefield Accelerator (AWA) decided to develop a solution with high cost-efficiency to fit in its budget. Some details about the development are presented in this paper.
 
slides icon Slides THXBA4 [8.544 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-NAPAC2019-THXBA4  
About • paper received ※ 29 August 2019       paper accepted ※ 31 August 2019       issue date ※ 08 October 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)