Author: Liu, Z.K.
Paper Title Page
TUPYP016
Quick Scanning Verification of a Monochromator Spindle Based Servo Control at BSRF  
 
  • Z.K. Liu, H. Liang
    IHEP, Beijing, People’s Republic of China
 
  A quick scanning monochromator built for Quick EXAFS experiments needs to perform 2 kinds of movements, one is fast movements in an oscillation way of the spindle, the other is step scan mode. Servo control has never been used on quick scanning monochromators. To verify the feasibility of the 2 modes on quick scanning monochromators by servo control, experiments are designed and carried out on a inhouse built air bearing spindle. An ACS controller is used to drive the motor, encoder provides the position feedback. A laser interferometer is used to measure the actual angular position of the spindle. Test method: The motor is controlled to move with a set trajectory of sinusoidal signals, and the feedback data from the interferometer and encoder are compared to verify the position and speed. The experiments show that with interferometer calibration, there is only 3% systematic error in the encoder feedback value. Overall the stepping mode can achieve a resolution of 0.4 arcsecond per step, and the scanning mode can achieve a 50 Hz, 0.08°sine signal tracking. It is possible to get better results by using lighter loads and motors with better performance.  
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPYP017 Design and Test of Precision Mechanics for High Energy Resolution Monochromator at the HEPS 51
 
  • L. Zhang, H. Liang, Z.K. Liu, W. Xu, Y. Yang, Y.S. Zhang
    IHEP, Beijing, People’s Republic of China
 
  A monochromator stands as a typical representative of optical component within synchrotron radiation light sources. High resolution monochromators (HRMs), which incorporate precision positioning, stability control, and various other technologies, are a crucial subclass within this category. The next generation of photon sources imposes higher performance standards upon these HRMs. In this new design framework, the primary focus is on innovating precision motion components. Rigorous analysis and experimentation have confirmed the effectiveness of this design. This structural model provides valuable reference for developing other precision adjustment mechanisms within the realm of synchrotron radiation.  
poster icon Poster TUPYP017 [3.641 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-MEDSI2023-TUPYP017  
About • Received ※ 01 November 2023 — Revised ※ 03 November 2023 — Accepted ※ 08 November 2023 — Issued ※ 04 February 2024
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPPP050 Quick scanning Channel-Cut crystal monochromator for millisecond time resolution EXAFS at HEPS 229
 
  • Y.S. Lu, H. Liang, Z.K. Liu, D.S. Shen, Z. Sun, Y. Yang, S. Zhang, Y.S. Zhang
    IHEP, Beijing, People’s Republic of China
 
  The design and capabilities of a Quick scanning Channel-Cut monochromator (QCCM) for HEPS are presented. The quick scan and step scan are realized by a torque motor directly driven Bragg axis, controlled by a servo controller. This design allows easy and remote control of the oscillation frequency and angular range, providing comprehensive control of QXAFS measure-ments. The cryogenically cooled Si (311) and Si(111) crystals, which extends the energy range from 4.8 keV-45 keV. The dynamic analysis verifies the rationality of the mechanical structure design. The device was fabri-cated and tested, results show an oscillation frequency up to 50Hz with a range of 0.8°, and a resolution of 0.2 arcsecond in step scan mode. This device demonstrates the feasibility of large range quick scan and step scan by a single servo control system.
Quick scanning Channel-Cut crystal monochromator
 
DOI • reference for this paper ※ doi:10.18429/JACoW-MEDSI2023-WEPPP050  
About • Received ※ 02 November 2023 — Revised ※ 05 November 2023 — Accepted ※ 08 November 2023 — Issued ※ 08 January 2024
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THOBM03
Progress and Core Technologies Development of Monochromators for HEPS  
 
  • H. Liang, M.W. Chen, X.B. Deng, Q.S. Diao, L. Gao, Z. Hong, G. Li, M. Li, Z.K. Liu, Y.S. Lu, D.S. Shen, W.F. Sheng, S.F. Wang, Y. Yang, Z.Y. Yue, L. Zhang, S. Zhang, Y.S. Zhang, A.Y. Zhou
    IHEP, Beijing, People’s Republic of China
 
  HEPS is the first low emittance 4th generation light source in China, as monochromators are often limiting the performance of beamlines, many challenges are faced to preserve the quality of the beam. In order to meet the stringent and versatile requirements of 12 in house developed monochromators for different beamlines, several core technologies have been studied and developed. Stability considerations, vibration measurement system and methods are introduced, stability below 10 nrad RMS are measured for operation conditions by laser interferometers. Thermal resistance study at low temperature was carried out, enabling more accurate FEA of cooling. Clamping deformation of crystals at low temperature are experimentally studied, slope errors below 0.1 microradian RMS are measured. Design and test results on different types of monochromators will also be presented. Results show that the in house developed monochromators are able to meet the requirements of HEPS beamlines.  
slides icon Slides THOBM03 [8.445 MB]  
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPPP023 Design and Test of a New Crystal Assembly for a Double Crystal Monochromator 313
 
  • Y. Yang, H. Liang, Z.K. Liu, Y.S. Lu, D.S. Shen, L. Zhang, S. Zhang, Y.S. Zhang
    IHEP, Beijing, People’s Republic of China
 
  Vertical diffraction monochromator is a typical optical device in synchrotron radiation device. Its main requirements and characteristics are high Angle accuracy and stability. Due to the high requirements of new light sources, high precision and high stability have become a common difficulty. This paper mainly introduces the design and test of an internal crystal module of HDCM. There are two main parts: the first crystal and the second crystal. The first crystal assembly includes crystal cooling and clamping, using microchannel edge cooling and flat plate clamping schemes. The second crystal component, through the motor to the top, drives the flexible hinge, and then realizes the rotation of the crystal. At the same time, the Angle monitoring system is designed. The design scheme is verified by processing. The shape of the clamping surface of a crystal component meets the requirements of use. The motion test of the two crystal components is carried out in the atmosphere, vacuum and low temperature vacuum environment, and the results are much higher than the required parameters. And the whole stability is tested. It has high stability.  
DOI • reference for this paper ※ doi:10.18429/JACoW-MEDSI2023-THPPP023  
About • Received ※ 02 November 2023 — Revised ※ 05 November 2023 — Accepted ※ 08 November 2023 — Issued ※ 19 December 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)