Author: Chritin, N.S.
Paper Title Page
TUPYP054 Mechanical Design of the Beam Gas Ionisation (BGI) Beam Profile Monitor for CERN Super Proton Synchrotron 114
 
  • M.T. Ramos Garcia, W. Andreazza, P. Bestmann, H. Bursali, N.S. Chritin, W. Devauchelle, A. Harrison, G. Khatri, M. McLean, C. Pasquino, F. Sanda, P. Schwarz, J.W. Storey, R. Veness, W. Vollenberg, C. Vollinger
    CERN, Meyrin, Switzerland
 
  The Beam Gas Ionisation (BGI) instrument of the Proton Synchrotron (PS), presently installed and operational, has been re-designed for the Super Proton Synchrotron (SPS), the following machine along the Large Hadron Collider (LHC) injector chain at CERN accelerator complex. Using the same detection technology, Timepix3, the SPS-BGI infers the beam profile from the electrons created by the ionisation of rest gas molecules and accelerated onto an imaging detector. This measurement method will allow for continuous, non-destructive beam size measurement in the SPS. In view of the upgrade, the design has been simplified and validated for integration, radio-frequency & impedance, high-voltage and ultra-high vacuum compatibility.  
DOI • reference for this paper ※ doi:10.18429/JACoW-MEDSI2023-TUPYP054  
About • Received ※ 24 October 2023 — Revised ※ 04 November 2023 — Accepted ※ 08 November 2023 — Issued ※ 14 November 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)