Paper | Title | Page |
---|---|---|
TUPH32 | Overview of Sesame Water Cooling System Design & Operation | 108 |
|
||
Funding: IAEA SESAME started operation in January 2017. In order to receive heat deposited in various synchrotron devices during operation, a low-conductivity water cooling system was installed. Within this paper the design, construction and operation of the water cooling system will be discussed, Both Hydraulic and Thermal Behavior of the system will be analyzed and discussed with numerical simulation means as well as real operation pressure and temperature data for the purpose of a better understanding of the cooling system |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH32 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEPH23 | FEA Simulations of the Aluminium Vacuum Chamber for LOREA Insertion Device at ALBA Synchrotron Light Source | 255 |
|
||
For LOREA, the new beamline at ALBA, the Insertion Device Apple-II helical out-vacuum undulator requires the installation of a suitable narrow-gap aluminium chamber. The chamber design is based on the standard ALBA aluminium chamber which has an internal elliptical cross section, where NEG coating is deposited and bending magnet (BM) radiation from the upstream dipole is dissipated on the chamber walls. For the standard chamber the upstream distributed absorber cannot protect the entire chamber from direct BM radiation because there is a limitation for its design: the beam impedance of the machine. Based on new studies of collective effects it has been concluded that it's possible to implement modifications on the upstream distributed absorber and protect the chamber from lateral collision of BM radiation keeping the beam impedance of the machine inside of a safe range. In spite of that still there is a contribution of the tails of BM radiation. In this paper we describe the behavior of the new aluminium vacuum chamber for different thermal load conditions using water and air for refrigeration. Also we present the design of the modified OFHC upstream distributed absorber. | ||
![]() |
Poster WEPH23 [0.609 MB] | |
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-WEPH23 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEPH24 | Design of an Integrated Crotch Absorber for ALBA Synchrotron Light Source | 258 |
|
||
This paper presents the design of an Integrated Crotch Absorber for the new beamline LOREA (Low-Energy Ultra-High-Resolution Angular Photoemission for Complex Materials at ALBA). The LOREA Insertion Device (ID) consists of an Apple II undulator with a period of 125 mm. For the current ALBA dipole chamber the ID vertical polarized light hits the upper and lower walls because of the very narrow vertical aperture between the cooling channels. To solve this problem some modifications must be implemented both in the dipole chamber and in the crotch absorber located inside of the dipole. The new crotch absorber, named Integrated Crotch Absorber, must absorb a significant part of the ID vertical polarized light in order to avoid radiation impinging at the post dipole chamber. The geometry of the Integrated Crotch Absorber is a combination of the conventional crotch and the distributed absorber done at PSI for ANKA. The design has been optimized taking into account the standard thermo-mechanical design criteria as well as the reflective effects of the ID radiation from the opening towards the walls of the dipole chamber. | ||
![]() |
Poster WEPH24 [1.046 MB] | |
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-WEPH24 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |