Seiji Thielk (RadiaBeam)
MOPB102
LLRF and pulse-to-pulse correction for a compact linac
270
The advent of c-band and x-band technology has made it possible to reduce the footprint of linear accelerators. Additionally, for industrial systems a more compact linac is enabling technology for burgeoning applications in security and defense. A key aspect to operating these machines in an industrial environments is stabilization of the amplitude and phase signals for the cavities. In this poster we present the design and recent results for a LLRF and pulse-to-pulse correction scheme utilizing an RFSoC based FPGA system.
  • J. Einstein-Curtis, J. Edelen, M. Kilpatrick
    RadiaSoft LLC
  • A. Diego, R. Agustsson, S. Thielk
    RadiaBeam
  • B. Hong, C. Liu, E. Nanni, F. Zuo, J. Merrick, L. Ruckman, S. Tantawi, Z. Li
    SLAC National Accelerator Laboratory
  • R. Berry
    RadiaBeam Technologies
Paper: MOPB102
DOI: reference for this paper: 10.18429/JACoW-LINAC2024-MOPB102
About:  Received: 29 Aug 2024 — Revised: 12 Sep 2024 — Accepted: 12 Sep 2024 — Issue date: 23 Oct 2024
Cite: reference for this paper using: BibTeX, LaTeX, Text/Word, RIS, EndNote
TUPB099
Engineering design of 402 MHz normal conducting coaxial window
522
RadiaBeam is fabricating a novel RF vacuum window for use with the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The window features a coaxial ceramic window between two waveguides, brazed as a single assembly. Unlike traditional pillbox window designs, this approach allows the outer diameter of the ceramic to decrease and the added benefit of water cooling the inner diameter of the ceramic. This paper covers the engineering design including details of key features, the impact of the unique RF design on manufacturability, and mechanical simulations. A status update on the fabrication is also provided with emphasis on the ceramic TiN coating and brazing process.
  • S. Thielk, R. Agustsson, S. Kutsaev
    RadiaBeam
  • A. Pronikov
    RadiaBeam Technologies
Paper: TUPB099
DOI: reference for this paper: 10.18429/JACoW-LINAC2024-TUPB099
About:  Received: 20 Aug 2024 — Revised: 21 Sep 2024 — Accepted: 21 Sep 2024 — Issue date: 23 Oct 2024
Cite: reference for this paper using: BibTeX, LaTeX, Text/Word, RIS, EndNote
TUPB100
Design of a 25 kW fundamental power coupler for conduction cooled Nb3Sn industrial linac
526
RadiaBeam is designing a 915 MHz, 25 kW CW Fundamental Power Coupler (FPC) to power a Nb3Sn coated superconducting radio-frequency (SRF) cavity. Unlike traditional FPCs for SRF cavities, the device relies only on conductive cooling by cryocoolers. The baseline design was adapted from the liquid helium cooled 805 MHz SNS FPC with the notable addition of an intermediate 50 K thermal intercept and associated RF shield. Engineering design details to address the thermomechanical, manufacturability, and structural challenges will be presented. Particular emphasis will be placed on static and dynamic heat load management along with finite element analysis to validate mechanical stability. Additionally, initial manufacturing studies of the coaxial window brazing will be discussed along with full device manufacturing and integration plans.
  • S. Thielk, R. Agustsson, S. Kutsaev
    RadiaBeam
  • A. Pronikov, A. Araujo Martinez
    RadiaBeam Technologies
  • J. Vennekate, G. Ciovati, R. Rimmer
    Thomas Jefferson National Accelerator Facility
Paper: TUPB100
DOI: reference for this paper: 10.18429/JACoW-LINAC2024-TUPB100
About:  Received: 20 Aug 2024 — Revised: 13 Sep 2024 — Accepted: 13 Sep 2024 — Issue date: 23 Oct 2024
Cite: reference for this paper using: BibTeX, LaTeX, Text/Word, RIS, EndNote
TUPB101
S-band RF pulse compressor for high-gradient carbon therapy linac
Novel hadron radiotherapy accelerator-based systems require a fast-imaging capability, synchronized with the hadron beam, to allow positioning and treating the tumor practically at the same time. Such systems must operate at high repetition rates (~1,000 pulses per second) to provide reasonable treatment times. Currently, Argonne and RadiaBeam are collaborating on a high-gradient carbon therapy linac project, ACCIL, based on 40 MV/m S-band accelerating structures. In order to operate at repetition rates, the structures must be powered by the 5 MW klystrons. However, high gradient operation requires quadruple of this power. Therefore, we developed a compact S-band RF pulse compressor based on an E-plane polarizer and a spherical cavity operating at 2856 MHz. It incorporates features such as a cut-off circular port opposite to the circular waveguide to facilitate vacuum pumping, along with cooling channels distributed around the cavity and polarizer to manage the thermal loads. The RF pulse compressor is expected to generate a flat 18 MW 300 ns flat-top RF pulse with a 62% efficiency. We will present the mechanical design and fabrication status of the device.
  • A. Araujo Martinez
    RadiaBeam Technologies
  • A. Smirnov, R. Agustsson, S. Thielk, S. Kutsaev
    RadiaBeam
  • V. Dolgashev
    SLAC National Accelerator Laboratory
Cite: reference for this paper using: BibTeX, LaTeX, Text/Word, RIS, EndNote