Performance of PIP-II high-beta 650 cryomodule after transatlantic shipping
198
After shipment to the Daresbury Lab and return to Fermilab, the prototype HB650 cryomodule underwent another phase of 2K RF testing to ascertain any performance issues that may have arisen from the transport of the cryomodule. While measurements taken at room temperature after the conclusion of shipment indicated that there were no negative impacts on cavity alignment, beamline vacuum, or cavity frequency, testing at 2K was required to validate other aspects such as tuner operation, cavity coupling, cryogenic system integrity, and cavity performance. Results of this latest round of limited 2K testing will be presented.
Paper: MOPB067
DOI: reference for this paper: 10.18429/JACoW-LINAC2024-MOPB067
About: Received: 22 Aug 2024 — Revised: 03 Sep 2024 — Accepted: 16 Sep 2024 — Issue date: 23 Oct 2024
THPB029
Optimization of static heat loads of the PIP-II cryomodules based on prototype HB650 cryomodule test results
695
During the first cool down of the prototype HB650 cryomodule (pHB650 CM), high static heat loads have been measured compared to the estimation. Several analysis and calculations have been performed to explain this difference which led to cool down this cryomodule two additional times. Before each cool down, repairs and upgrades have been done, and instrumentations were added to identify the issues and quantify their impact on the heat loads. Based on these findings, the production cryomodule design and assembly process have been updated to align the future heat loads measurements with the estimations.
Paper: THPB029
DOI: reference for this paper: 10.18429/JACoW-LINAC2024-THPB029
About: Received: 23 Aug 2024 — Revised: 21 Sep 2024 — Accepted: 21 Sep 2024 — Issue date: 23 Oct 2024