Cravatta Andrew
THPB028
Excellent performance of 650 MHz single-cell niobium cavity after electropolishing
692
The electropolishing process and cathodes have undergone modification and optimization for both low- and high-beta 650 MHz five-cell niobium cavities. Cavities treated with these novel electropolishing conditions exhibited superb surface quality and performance in baseline tests. Nonetheless, due to administrative constraints on project cavities, maximum gradient performance testing was not conducted. This paper presents a study conducted on a single-cell 650 MHz cavity utilizing the optimized electropolishing conditions, highlighting the maximum performance attained for this specific cavity.
  • V. Chouhan, A. Netepenko, A. Cravatta, D. Bice, G. Wu, O. Melnychuk, T. Khabiboulline
    Fermi National Accelerator Laboratory
  • B. Guilfoyle, T. Reid
    Argonne National Laboratory
Paper: THPB028
DOI: reference for this paper: 10.18429/JACoW-LINAC2024-THPB028
About:  Received: 20 Aug 2024 — Revised: 07 Sep 2024 — Accepted: 07 Sep 2024 — Issue date: 23 Oct 2024
Cite: reference for this paper using: BibTeX, LaTeX, Text/Word, RIS, EndNote