Author: Tamura, J.
Paper Title Page
MOPLR063 Development of H0 Beam Diagnostic Line in MEBT2 of J-PARC Linac 277
 
  • J. Tamura, A. Miura, T. Morishita
    JAEA/J-PARC, Tokai-mura, Japan
  • H. Ao
    FRIB, East Lansing, USA
  • T. Maruta
    J-PARC, KEK & JAEA, Ibaraki-ken, Japan
  • T. Miyao
    KEK, Ibaraki, Japan
 
  In the Japan Proton Accelerator Research Complex (J-PARC) linac, H0 particles arising from collisions of accelerated H beams with residual gas are considered as one of the key factors of the residual radiation in the high energy accelerating section. To analyze the H0 and the accelerated H particles, the bump magnet system was designed and produced. The H0 beam diagnostic line consists of four horizontal bending magnets, non-destructive beam position monitor and wire scan beam profile monitor. In the 2015 summer maintenance period of the J-PARC, the new diagnostic line was constructed in the beam transport (MEBT2), which is the matching section from separated-type drift tube linac (SDTL) to annular-ring coupled structure linac (ACS). In the beam commissioning, we experimentally confirmed that the accelerated 190 MeV H beams are horizontally shifted as expected with the magnetostatic field simulation and the particle tracking simulation.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2016-MOPLR063  