  X ray sources for linear accelerators continue to be a necessary requirement for industries such as medical, inspection, and nondestructive test equipment. Future requirements for such sources are; low cost, compact packaging and high performance of the RF source for electron acceleration. The magnetron has proven to be a perfect source over other RF sources for linear accelerator use. Because of its simple design, low cost per output, small size and proven performance it meets all required characteristics. New Japan Radio Co., Ltd. has improved and modified its linac magnetrons' performance and characteristics enabling easy matching to the linac modulator, long life and maximum output power. This paper will provide a detailed explanation on the improved magnetron design methodology and its effects on the performance of these magnetrons installed in linac systems. These technologies have been utilized successfully on a commercial level worldwide over the last few years. The technology has been deployed into linac systems operating in S and X band and soon C band, at various output power levels.  