Author: Gonnella, D.
Paper Title Page
TUPRC025 Low Temperature Nitrogen Baking of a Q0 SRF Cavities 472
 
  • P.N. Koufalis, F. Furuta, M. Ge, D. Gonnella, J.J. Kaufman, M. Liepe, J.T. Maniscalco, R.D. Porter
    Cornell University (CLASSE), Cornell Laboratory for Accelerator-Based Sciences and Education, Ithaca, New York, USA
 
  Nitrogen-doping has led to an unprecedented increase in the intrinsic quality factor of bulk-niobium superconducting RF cavities. So far, high temperature baking in a nitrogen atmosphere is used almost exclusively to dope cavities. Recently, we have set focus on low temperature baking to produce similar performance increases and we present those results here.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2016-TUPRC025  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPLR011 Performance of the Novel Cornell ERL Main Linac Prototype Cryomodule 492
 
  • F. Furuta, J. Dobbins, R.G. Eichhorn, M. Ge, D. Gonnella, G.H. Hoffstaetter, M. Liepe, T.I. O'Connell, P. Quigley, D.M. Sabol, J. Sears, E.N. Smith, V. Veshcherevich
    Cornell University (CLASSE), Cornell Laboratory for Accelerator-Based Sciences and Education, Ithaca, New York, USA
 
  The main linac cryomodule (MLC) for the future energy-recovery linac (ERL) based X-ray light source at Cornell has been designed, fabricated, and tested. It houses six 7-cell SRF cavities with individual higher order-modes (HOMs) absorbers, cavity frequency tuners, and one magnet/BPM section. Cavities have achieved the specification values of 16.2MV/m with high-Q of 2.0·1010 in 1.8K in continuous wave (CW) mode. During initial MLC cavity testing, we encountered some field emission, reducing Q and lowering quench field. To overcome field emission and find optimal cool-down parameters, RF processing and thermal cycles with different cool-down conditions has been done. Here we report on these studies and present final results from the MLC cavity performance.  
poster icon Poster TUPLR011 [2.389 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2016-TUPLR011  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPLR012 HOM Measurements for Cornell's ERL Main Linac Cryomodule 496
 
  • F. Furuta, R.G. Eichhorn, M. Ge, D. Gonnella, G.H. Hoffstaetter, M. Liepe, P. Quigley, V. Veshcherevich
    Cornell University (CLASSE), Cornell Laboratory for Accelerator-Based Sciences and Education, Ithaca, New York, USA
 
  The main linac cryomodule (MLC) for a future energy-recovery linac (ERL) based X-ray source at Cornell has been designed, fabricated, and tested. It houses six 7-cell SRF cavities with individual higher order-modes (HOMs) absorbers, cavity frequency tuners, and one magnet/BPM section. All HOMs in MLC have been scanned in 1.8K. The results show effective damping of HOMs, and also agree well with simulation results and the previous HOM scan results on one 7-cell cavity prototype test cryomodule. Here we present detailed results from these HOM studies.  
poster icon Poster TUPLR012 [2.773 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2016-TUPLR012  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPLR025 Optimal Nitrogen Doping Level to Reach High Q0 523
 
  • D. Gonnella, T. Gruber, J.J. Kaufman, P.N. Koufalis, M. Liepe, J.T. Maniscalco
    Cornell University (CLASSE), Cornell Laboratory for Accelerator-Based Sciences and Education, Ithaca, New York, USA
 
  Funding: NSF and US DOE
New continuous wave (CW) accelerators such as LCLS-II at SLAC require many SRF cavities operating in the medium field region at unprecedented high Q. In order to achieve this demanding goal, nitrogen-doping of the SRF cavities will be used. Nitrogen-doping has been shown to affect the BCS resistance both by a lowering of Rbcs at low fields and by the introduction of an anti-Q slope which enables the Q to continue increasing as the RF field is increased. The exact strength of this anti-Q slope is heavily dependent on the doping recipe and specifically the mean free path of the RF penetration layer of the doped cavities. In addition to its effect on Rbcs, the mean free path affects the amount of residual resistance obtained due to trapped magnetic flux. We have analyzed nine cavities prepared with different levels of nitrogen-doping to understand how BCS and residual resistance are affected by changes in the mean free path. Here we present a model based on these experimental results to predict the optimal doping level to reach the maximum Q at 16 MV/m based on the ambient magnetic field conditions. We find that if the cavities can be cooled with small amounts of trapped flux, moderate nitrogen-doping is better, while if they will have large amounts of trapped flux, lighter dopings should be used.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2016-TUPLR025  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)