Author: Benedetti, S.
Paper Title Page
MOPLR048 Fabrication and Testing of a Novel S-Band Backward Travelling Wave Accelerating Structure for Proton Therapy Linacs 237
SPWR023   use link to see paper's listing under its alternate paper code  
 
  • S. Benedetti, T. Argyropoulos, C. Blanch Gutiérrez, N. Catalán Lasheras, A. Degiovanni, D. Esperante Pereira, M. Garlaschè, J. Giner Navarro, A. Grudiev, G. McMonagle, A. Solodko, M.A. Timmins, R. Wegner, B.J. Woolley, W. Wuensch
    CERN, Geneva, Switzerland
  • D. Esperante Pereira
    IFIC, Valencia, Spain
 
  Compact and more affordable, facilities for proton therapy are now entering the market of commercial medical accelerators. At CERN, a joint collaboration between CLIC and TERA Foundation led to the design, fabrication and testing of a high gradient accelerating structure prototype, capable of halving the length of state-of-art light ion therapy linacs. This paper focuses on the mechanical design, fabrication and testing of a first prototype. CLIC standardized bead-pull measurement setup was used, leading to a quick and successful tuning of the prototype. The high power tests will soon start in order to prove that the structure can withstand a very high accelerating gradient while suffering no more than 10-6 breakdown per pulse per meter (bpp/m), resulting in less than one breakdown per treatment session.  
poster icon Poster MOPLR048 [2.804 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2016-MOPLR048  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPLR049 Design of a 750 MHz IH Structure for Medical Applications 240
SPWR022   use link to see paper's listing under its alternate paper code  
 
  • S. Benedetti, A. Grudiev, A. Latina
    CERN, Geneva, Switzerland
 
  Low velocity particles are critical in every hadron accelerator chain. While RFQs nicely cover the first MeV/u range, providing both acceleration and bunching, energies higher than few MeV/u require different structures, depending on the specific application. In the framework of the TULIP project [1], a 750 MHz IH structure was designed, in order to cover the 5-10 MeV/u range. The relatively high operating frequency and small bore aperture radius led the choice towards TE mode structures over more classic DTLs. Hereafter, the RF regular cell and end cell optimization is presented. An innovative solution to compensate dipole kicks is discussed, together with the beam dynamics and the matching with the 5 MeV 750 MHz CERN RFQ [2]. This structure was specifically designed for medical applications with a duty cycle of about 1 ', but can easily adapted to duty cycles up to 5 %, typical of PET isotopes production in hospitals.  
poster icon Poster MOPLR049 [3.212 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2016-MOPLR049  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)