Paper | Title | Page |
---|---|---|
TUPP113 | High RF Power Test of Coupled RFQ-SFRFQ Cavity | 689 |
SUPG034 | use link to see paper's listing under its alternate paper code | |
|
||
Funding: This work was supported in part by the National Natural Science Foundation of China under Grant No. 11075008, 11079001 and 11175009. A new combined accelerator that couples radio frequency quadrupole (RFQ) and separated function radio frequency quadrupole (SFRFQ) in a single cavity has been designed and manufactured. Recently, the performance of the cavity under high RF power was tested with an upgraded RF power source. The inter-vane voltages of both RFQ section and SFRFQ section were measured by using high purity germanium detector and the corresponding measurement system. The measured shunt impedance is about 546.9 kΩ•m, which means the cavity needs 19.5 kW for the designed inter-vane voltage of 65 kV. The results are well consistent with the cavity design. |
||
![]() |
Poster TUPP113 [0.764 MB] | |
THPP115 | PKU 2.45 GHz Microwave Driven H− Ion Source Performance Study | 1120 |
|
||
Funding: This work is supported by the National Science Foundation of China (Grant Nos. 11175009, 91126004 and 11305004) In a high intensity volume-produced H− ion source, H− ion production processes are great affected by electron temperature and gas pressure distribution within the discharge chamber. The H-/e ratio within an extracted H− ion beam is much depended on the electron absorption within the extraction system. At Peking University (PKU), lots of experiments were carried out for better understanding H− processes and electron dump on our 2.45 GHz microwave driven Cs-free permanent magnet volume-produced H− source. Detail will be given in this paper. Author to whom correspondence should be addressed. Electronic mail: sxpeng@pku.edu.cn. |
||
![]() |
Poster THPP115 [2.252 MB] | |
THPP138 | Measurements of Beam Current and Energy-Dispersion for Ion Beam with Multi-Components | 1185 |
|
||
Funding: This work is supported by the National Science Foundation of China(Grant Nos. 91126004). The multi-component ion beam is very common in nuclear physics, materials physics and most kind of ion source. But the diagnosis of multi-component ion beam [1] can be difficult because of its complex composition and irregular energy-dispersion. We need an effective way to analyzing the multi-component ion beam. There is a multi-component ion beam whose total beam current varies from 1 mA to 50mA and the beam energy can be 20keV to 150keV. In this paper, four methods to analyzing this multi-component ion beam are described, which are Faraday cup array method, fluorescent screen with Faraday cup, movable aperture with conductive fluorescent screen, and current calibration method, respectively. The distributions and currents of the separated ion beams are obtained by means of the four methods, and the current and energy-dispersion of each component might be measured at the same time. This is of special interest for beams with multi-components. Detailed description and comparison of the four methods are discussed in this paper. Correspondence Author:Peng ShiXiang. Email: sxpeng@pku.edu.cn |
||
![]() |
Poster THPP138 [0.419 MB] | |