Author: Mizuno, A.
Paper Title Page
MOPP094 Latest Improvements of the SPring-8 Linac for High Reliability 276
 
  • S. Suzuki, H. Dewa, H. Hanaki, T. Kobayashi, T. Magome, A. Mizuno, T. Taniuchi, K. Yanagida
    JASRI/SPring-8, Hyogo-ken, Japan
  • T. Asaka
    RIKEN SPring-8 Center, Sayo-cho, Sayo-gun, Hyogo, Japan
 
  In order to perform stable injection to the 8GeV SPring-8 storage ring, which is performing the top-up operation, the high reliability of the linac has been advanced as follows: For reduction of phase variations caused by the waveguide deformation due to the variations of temperature or atmospheric pressure, the waveguide circuit of SF6 enclosure type, which fed RF powers to the bunching section, was replaced with that of vacuum type. And S-band 10MW circulators and isolators of vacuum type were adopted for the first time in the world. The timing system was improved so that the interval time of the beam injection into the 8GeV booster synchrotron and the 1.5 GeV NewSUBARU storage ring has been reduced to 1 sec from 15 seconds, respectively, even in the top-up operation of both storage rings. As a result, the stored current by the top-up operation were further stabilized. The stored current of the NewSUBARU storage ring was stabilized to 0.18% from 0.31%. The electron gun cathode assembly has been developed to reduce the dark emission from a grid plate by the double grid method and the electrolytic polishing.  
 
TUPP105 Storage Ring as a Linac Beam Monitor – Its Operation and Contribution to the Stable Top-up Injection 668
 
  • Y. Shoji
    LASTI, Hyogo, Japan
  • T. Asaka, H. Dewa, H. Hanaki, T. Kobayashi, Y. Minagawa, A. Mizuno, T. Shinomoto, S. Suzuki, Y. Takemura, T. Taniuchi, K. Yanagida
    JASRI/SPring-8, Hyogo-ken, Japan
 
  We have used the electron storage ring, NewSUBARU, as a beam monitor of the SPring-8 linac. The time and transverse profiles of the injected linac beam are recorded in a frame of a dual-sweep streak camera. A measurements through synchrotron or betatron oscillation in the ring gives multi-dimensional beam structure. The system functions as a final check of the linac beam. It gives the time profile and energy profile or transverse emittance, which includes Twiss parameters. It measures parameters of one linac bunch in a long macro pulse. A shot-by-shot measurement gives beam fluctuations. We report how we use the system and its contribution to the stable top-up operation. The beam loading effect on the bunch energy was obtained by bunch-by-bunch energy profile measurements. It confirmed the optimization of the ECS (Energy Compression System) parameters. The single shot bunch-by-bunch vertical emittance measurement proved the difference between the front bunch and the following bunches. The same measurement showed a timing jitter of the electron gun pulse although the rf synchronization was perfect. This jittering had made the injection efficiency unstable.