Paper | Title | Page |
---|---|---|
TUPP018 | Analysis of Systematic and Random Error in SRF Material Parameter Calculations | 465 |
|
||
Funding: NSF Career award PHY-0841213 and DOE award ER41628 To understand the relationship between an RF cavity’s performance and the material on its surface, one must look at various parameters, including energy gap, mean free path, and residual resistance. Though SRIMP fits for seven parameters, three parameters are eliminated using measurement and literature values, and the uncertainty of the fit of the remaining four parameters is further reduced by synthesizing two 3-parameter fits, each from a different data set. To study random error, Monte Carlo simulations were performed of ideal data with added noise; for systematic error, contour plots of normalized residual sum of squares (RSS) of the polymorphic fit on inputted data were generated. |
||
![]() |
Poster TUPP018 [1.183 MB] | |
MOPP016 | Extracting Superconducting Parameters from Surface Resistivity by Using Inside Temperature of SRF Cavities | 80 |
|
||
The surface resistance of an RF superconductor depends on the surface temperature, the residual resistance and various superconductor parameters. These parameters can be determined by measuring the quality factor of a SRF cavity in helium-baths of different temperatures. The surface resistance can be computed from Q0 for any cavity geometry, however it is less simple to determine the temperature of the surface when only the temperature of the helium bath is known. Traditionally, it was approximated that the surface temperature on the inner surface of the cavity is the same as the temperature of the bath. This is a good approximation at small RF-field losses on the surface, but to determine the field dependence of Rs, one cannot be restricted to small field losses. Here we show how computer simulations can be used to determine the inside temperature so that Rs(Tin) can then be used to extract superconductor parameters. The computer code combines the well-known programs HEAT and SRIMP. We find that the error of the incorrect fitting method is about 10% at high RF-fields. | ||
MOPP017 | Cool Down and Flux Trapping Studies on SRF Cavities | 84 |
MOPOL07 | use link to see paper's listing under its alternate paper code | |
|
||
Recent results from Cornell and FNAL have shown that cool down rate can have a strong impact on the residual resistance of a superconducting RF cavity during operation. We have studied the effect of cool down rate, gradient, and external magnetic field during cool down on the residual resistance of an EP, EP+120C baked, and nitrogen-doped cavities. For each cavity, faster cool down and large gradient resulted in lower residual resistance in vertical test. The nitrogen-doped cavities showed the largest improvement with fast cool down, while the EP+120C cavity showed the smallest. The cavities were also placed in a uniform external magnetic field and residual resistance was measured as a function of applied field and cool down rate. We show that the nitrogen-doped cavity was the most susceptible to losses from trapped flux and the EP+120C cavity was least susceptible. These measurements provide new insights into understanding the physics behind the observed impact of cool down rates and gradients on the performance of cavities with differing preparations. | ||
MOPP018 | Nitrogen-Doped 9-Cell Cavity Performance in the Cornell Horizontal Test Cryomodule | 88 |
|
||
Funding: U.S. Department of Energy Cornell has recently completed construction and qualification of a horizontal cryomodule capable of holding a 9-cell ILC cavity. A nitrogen-doped niobium 9-cell cavity was assembled into the Horizontal Test Cryomodule (HTC) with a high Q input coupler and tested. We report on results from this test of a nitrogen-doped cavity in cryomodule and discuss the effects of cool down rate and thermal cycling on the residual resistance of the cavity. |
||
MOPP019 | Nb3Sn Materials Studies | 92 |
SUPG016 | use link to see paper's listing under its alternate paper code | |
|
||
Nb3Sn is a very promising material for use in SRF cavity applications, potentially offering significant improvements in quality factor and energy gradient compared to niobium. In order to better understand how to optimize this material for SRF applications, Nb3Sn samples were prepared at Cornell via vapor deposition, using varying parameters in the coating process. Microscopic studies were performed with SEM/EDX, and studies were performed on bulk samples to measure secondary electron yield, energy gap, and upper critical magnetic field. The results are presented here, with discussion for how they might point the way towards reaching even higher fields in Nb3Sn cavities. | ||
![]() |
Poster MOPP019 [2.742 MB] | |
TUIOC03 | Nb3Sn - Present Status and Potential as an Alternative SRF Material | 431 |
SUPG017 | use link to see paper's listing under its alternate paper code | |
|
||
Nb3Sn is a material that has the potential to have a transformative impact on SRF linacs. Due to its large critical temperature of approximately 18 K, Nb3Sn cavities can have far smaller surface resistances at a given temperature than standard Nb cavities. This could significantly reduce the costs for infrastructure and power in cryoplants for large CW linacs. In addition, the predicted superheating field of Nb3Sn is approximately double that of Nb, potentially doubling the maximum energy gradient. This would significantly decrease the size and cost of high energy linacs. In this work, we present recent progress in research and development for this promising material. | ||
![]() |
Slides TUIOC03 [3.357 MB] | |
![]() |
Poster TUIOC03 [2.046 MB] | |
TUPP016 |
Cornell ERL cavity production and vertical test results | |
|
||
The Cornell ERL 7-cell cavities for the Main Linac Cryomodule (MLC), six 7-cells in total- have been fabricated, processed, and tested in the Cornell Laboratory for Accelerator-based Sciences and Education (CLASSE) vertical test pit. All have surpassed the specification values (Eacc=16.2MV/m with Qo of 2.0·1010 at 1.8K). In fact, the achieved Qo during vertical test were much higher than specs, the average of Qo is almost 3·1010 at 1.8K. In this poster, we will describe about our ERL cavity fabrication, preparation, and vertical testing results. | ||
THPP016 | Nitrogen-Treated Cavity Testing at Cornell | 866 |
|
||
Funding: U.S. Department of Energy Recent results from Cornell, FNAL, and TJNAF have shown that superconducting RF cavities given a heat treatment in a nitrogen atmosphere show higher Q0 at operating gradients at 2.0 K than standard SRF cavities. Here we present on recent results at Cornell in which five single cell cavities and three 9-cell cavities were tested after receiving various nitrogen-doping treatments. Cavity performance was correlated with treatment, and samples treated with the cavities were analyzed with SIMS. These results provide new insights into the science behind the excellent performance that is observed in these cavities. |
||
THPP017 | Beam-Based HOM Studies of the Cornell Energy Recovery Linac 7-Cell SRF Cavity | 869 |
|
||
Funding: NSF Grant DMR-0807731 The 1.3 GHz 7-cell SRF cavity for the Cornell ERL main linac is optimized for high beam current ERL operation with injected CW beam currents of 100 mA. Beam stability at 100 mA requires very strong damping of the Higher-Order-Modes (HOM) in the cavity by HOM beamline absorbers at the ends of the cavity. To verify the optimized design of the cavity and the HOM damping scheme, a prototype 7-cell main linac cavity was installed into the Cornell Horizontal Test Cryomodule (HTC), and inserted into the beamline of the Cornell ERL high current photo-injector. A beam-based method was then used to search for the presence of dangerous HOMs. Individual HOMs were excited using a charge-modulated beam, after which their effect upon an unmodulated beam was observed using a BPM. Data collected was used to calculate loaded Q of observed HOMs. Results show that it is very unlikely that HOMs will cause BBU in the Cornell ERL. In addition, measurements of the temperature rise of the HOM absorber rings during high current CW beam tests were consistent with simulations, indicating that the optimized main linac cavity is capable of operating at the specified current of 100mA in an ERL configuration. |
||
THPP018 | Sample Plate Studies Using a High Field TE Cavity With Thermometry Mapping System | 873 |
|
||
Funding: NSF Career Grant PHY-0841213 A TE-Mode sample plate cavity capable of sustaining peak fields of >90 mT on the surface of a 10cm diameter sample plate has been developed and tested at Cornell. A thermometry mapping system composed of 40 Allen-Bradley resistors, mounted on the outside of the sample plate, is capable of measuring the surface resistance of the sample with a resolution of 1 nOhm and a spatial resolution of 0.5 cm. In this paper we present the design and expected performance of this high field TE cavity, and show data taken with a sample plate of niobium as well as results from tests qualifying the performance of the thermometry mapping system. |
||