Author: Lawangare, N.
Paper Title Page
MOPP007 SF6 Gas Monitoring and Safety for DC Electron Beam Accelerator at EBC, Kharghar, Navi Mumbai 61
 
  • S.K. Suneet, S. Acharya, S. Banerjee, R. Barnwal, D. Bhattacharjee, N. Chaudhary, R.B. Chavan, K.P. Dixit, S. Gade, L.M. Gantayet, S.R. Ghodke, S. Gond, B.S. Israel, D. Jayaprakash, N. Lawangare, K. Mahender, R.L. Mishra, K.C. Mittal, B. Nayak, S. Nayak, R. Patel, R.N. Rajan, P.C. Saroj, D.K. Sharma, V. Sharma, M.K. Srvastava, D.P. Suryaprakash, N.T. Thakur, R. Tiwari, A. Waghmare
    BARC, Mumbai, India
 
  A 3 MeV, 30kW DC Industrial electron beam accelerator has been designed, commissioned and tested at Electron beam centre, Kharghar. The accelerator has been tested upto 5 kW power level with SF6 gas at 6 kg/cm2. The accelerating column, high voltage multiplier column, electron gun and its power supply are housed in accelerator tank, which is filled with SF6 gas as gaseous insulator at 6 kg/cm2. The SF6 gas is being used due to high dielectric strength and excellent heat transfer characteristics. The SF6 gas is non toxic and non carcinogenic. The SF6 gas replaces oxygen hence the TLV (threshold limiting value) is 1000 ppm for inhaled gas for persons working on the SF6 gas handling system. The SF6 gas is being green house gas, leak tightness has to monitor in the system and leak if any should be repaired. The gas should be used, recycled and reuse and thus saving the environment. This paper describes the safety and monitoring of the SF6 gas leak, quality and precautions in 3MeV accelerator.  
poster icon Poster MOPP007 [1.389 MB]