Author: Joung, M.J.
Paper Title Page
MOPP081 The ECT System for RAON's Cavities 242
 
  • M.J. Joung, Y. Jung, H.J. Kim
    IBS, Daejeon, Republic of Korea
 
  The ECT system is in use for Nb surface control in many laboratories. This system can inspect Nb surface quickly using high resolution. The ECT system for RAON's cavity was made with the feature : It has 3-axis acting probe movement system, It can inspect big size of Nb sheet, which is 1m by 1m and It contain the analysis program that can show the result as 2D and 3D image as well as relative figure of surface level. The standard sample was made with various sizes of defects using the same Nb sheet that was used to make RISP cavity. The ECT system conditioining was carried out to optimize ECT operation on the frequency, the range is from 300kHz to 2MHz. The result of 900 kHz shows the strongest signal. The conditioning experiment on other parameter will be carried out in near future. .  
 
TUPP084 Surface Treatment Facilities for SCRF Cavities at RISP 619
 
  • J. Joo, D. Jeon, M.J. Joung, Y. Jung, H.J. Kim, M. Lee
    IBS, Daejeon, Republic of Korea
 
  Rare Isotope Science Project is engaged in the fabrication of four types of superconducting RF cavities. The surface treatment is one of the important processes of superconducting RF cavity fabrication. New superconducting RF cavity processing systems have been designed and developed for the etching of niobium in buffered chemical polish at RISP. The safety precautions used in protecting the operator from the acids used in the etchant and from the fumes given of during the process are discussed. All of the new hardware will be located in RISP Munji Superconducting Cavity Test Facility.