Author: Barkley, W.C.
Paper Title Page
MOPP107 Results from the Installation of a New 201 MHz RF System at LANSCE 303
 
  • J.T.M. Lyles, C.L. Arnold, W.C. Barkley, J. Davis, A.C. Naranjo, M.S. Prokop, D. Rees, G. M. Sandoval, Jr.
    LANL, Los Alamos, New Mexico, USA
  • D. Baca, R.E. Bratton, R.D. Summers
    Compa Industries, Inc., Los Alamos, New Mexico, USA
 
  Funding: Work supported by the United States Department of Energy, National Nuclear Security Agency, under contract DE-AC52-06NA25396.
The LANSCE RM project is restoring the linac to it’s original high power capability after the power grid tube manufacturer could no longer provide triodes that could consistently meet our power requirements. High duty factor Diacrodes® now supply RF power to the largest DTL tank. These tetrodes reuse the existing infrastructure including water-cooling systems, coaxial transmission lines, high voltage power supplies and capacitor banks. The power amplifier system uses a combined pair of LANL-designed cavity amplifiers using the TH628L Diacrode® to produce as much as 3.5 MW peak and 420 kW of mean power. A digital low level RF control system was developed to complement these new linear amplifiers. Design and testing was completed in 2012, with commercialization following in 2013. The first installation is commissioned. The two remaining high power RF systems for tanks 3 and 4 will be replaced in subsequent years using a hybrid old/new RF system until the changeover is complete. Features and operating results of the replacement system are summarized, along with observations from the rapid-paced installation project.