TUPB006 Stability Performance of the Injector for SACLA/XFEL at SPring-8 486
 
  • T. Asaka, T. Hasegawa, T. Inagaki, H. Maesaka, T. Ohshima, Y. Otake, S. Takahashi, K. Togawa
    RIKEN SPring-8 Center, Sayo-cho, Sayo-gun, Hyogo, Japan
 
  To realize the SACLA, it is necessary to obtain stabilities of 10-4 and 50 fs in the amplitude and time of an acceleration voltage, respectively. The achievement of the rf stabilities were almost satisfactory for the target values. Consequently, the 7 GeV beam energy stability was 0.02% (std.) or less. However, there was XFEL power variation caused by a variation of a beam position in a 40 MeV injector section. A periodically changed beam position of 40 μm (std.) was found out at a cycle of 2 s by Fourier transform method using BPM data. The temperatures of all the injector rf cavities are controlled within 28±0.04˚C by a controller using the cooling water. The AC power supplies of the controller to heat the cooling water are operated at 0.5 Hz by pulse width modulation control with alternatively turning on or off. The strong correlation between laser intensity variation and the modulation frequency of the AC power supplies was found out. We are planning to improve the cavity temperature variation in the order of less than 0.01˚C with DC power supplies to establish continuously regulated the cavity temperature. This plan will reduce the XFEL power variation.