SUPB014 RF Setup of the MedAustron RFQ 35
 
  • B. Koubek, A. Schempp, J.S. Schmidt
    IAP, Frankfurt am Main, Germany
  • J. Haeuser
    Kress GmbH, Biebergemuend, Germany
 
  A Radio Frequency Quadrupole (RFQ) was built for the injector of the cancer treatment facility MedAuston in Austria. For the RF design simulations were performed using CST Microwave Studio and the structure was manufactured by Firma Kress in Biebergemuend, Germany. The simulations and the RF setup of the delivered RFQ are presented in this paper.  
 
SUPB017 Tuning Studies on 4-rod-RFQs 44
 
  • J.S. Schmidt, B. Klump, B. Koubek, A. Schempp
    IAP, Frankfurt am Main, Germany
 
  A NI LabVIEW based Tuning Software has been devel- oped to structure the tuning process of 4-rod Radio Fre- quency Quadrupole s (RFQs). Its results are compared to measurement data of 4-rod RFQs in different frequency ranges. For the optimization of RFQ design parameters, a certain voltage distribution along the electrodes of an RFQ is assumed. Therefore an accurate tuning of the voltage distribution is very important for the beam dynamic prop- erties of an RFQ. A variation can lead to particle losses and reduced beam quality especially at higher frequencies. Our electrode design usually implies a constant longitudi- nal voltage distribution. For its adjustment tuning plates are used between the stems of the 4-rod-RFQ. These pre- dictions are based, in contrast to other simulations, on mea- surements to define the characteristics of the RFQ as it was build - not depending on assumptions of the design. This will lead to a totally new structured process of tuning 4- rod-RFQs in a broad range of frequencies by using the pre- dictions of a software. The results of these studies are pre- sented in this paper.  
 
THPB046 RF Setup of the MedAustron RFQ 957
 
  • B. Koubek, A. Schempp, J.S. Schmidt
    IAP, Frankfurt am Main, Germany
  • J. Haeuser
    Kress GmbH, Biebergemuend, Germany
 
  A Radio Frequency Quadrupole (RFQ) was built for the injector of the cancer treatment facility MedAuston in Austria. For the RF design simulations were performed using CST Microwave Studio and the structure was manufactured by Firma Kress in Biebergemuend, Germany. The simulations and the RF setup of the delivered RFQ are presented in this paper.  
 
THPB049 Tuning Studies on 4-Rod-RFQs 963
 
  • J.S. Schmidt, B. Klump, B. Koubek, A. Schempp
    IAP, Frankfurt am Main, Germany
 
  A NI LabVIEW based Tuning Software has been devel- oped to structure the tuning process of 4-rod Radio Fre- quency Quadrupole s (RFQs). Its results are compared to measurement data of 4-rod RFQs in different frequency ranges. For the optimization of RFQ design parameters, a certain voltage distribution along the electrodes of an RFQ is assumed. Therefore an accurate tuning of the voltage distribution is very important for the beam dynamic prop- erties of an RFQ. A variation can lead to particle losses and reduced beam quality especially at higher frequencies. Our electrode design usually implies a constant longitudi- nal voltage distribution. For its adjustment tuning plates are used between the stems of the 4-rod-RFQ. These pre- dictions are based, in contrast to other simulations, on mea- surements to define the characteristics of the RFQ as it was build - not depending on assumptions of the design. This will lead to a totally new structured process of tuning 4- rod-RFQs in a broad range of frequencies by using the pre- dictions of a software. The results of these studies are pre- sented in this paper.