Author: Popielarski, L.
Paper Title Page
MOPLB10 FRIB Technology Demonstration Cryomodule Test 165
 
  • J. Popielarski, E.C. Bernard, S. Bricker, S. Chouhan, C. Compton, A. Facco, A. Fila, L.L. Harle, M. Hodek, L. Hodges, S. Jones, M. Leitner, D. R. Miller, S.J. Miller, D. Morris, R. Oweiss, J.P. Ozelis, L. Popielarski, K. Saito, N.R. Usher, J. Weisend, Y. Zhang, S. Zhao, Z. Zheng
    FRIB, East Lansing, Michigan, USA
  • M. Klaus
    Technische Universität Dresden, Dresden, Germany
 
  A Technology Demonstration Cryomodule (TDCM) has been developed for a systems test of technology being developed for FRIB. The TDCM consists of two half wave resonators (HWRs) which have been designed for an optimum velocity of β=v/c=0.53 and a resonant frequency of 322 MHz. The resonators operate at 2 K. A superconducting 9 T solenoid is placed in close proximity to one of the installed HWRs. The 9 T solenoid operates at 4 K. A complete systems test of the cavities, magnets, and all ancillary components is presented in this paper.
This material is based upon work supported by the U.S. Department of Energy Office of Science under Cooperative Agreement DE SC0000661.
 
slides icon Slides MOPLB10 [2.530 MB]  
 
MOPB070 Quality Control of Cleanroom Processing Procedures of SRF Cavities for Mass Production 339
 
  • R. Oweiss, K. Elliott, A. Facco, M. Hodek, I.M. Malloch, J. Popielarski, L. Popielarski, K. Saito
    FRIB, East Lansing, Michigan, USA
 
  Funding: This material is based upon work supported by the U.S. Department of Energy Office of Science under Cooperative Agreement DE-SC0000661.
Quality control is a key factor in the success of SRF cavity mass production. This paper summarizes ongoing research at the Facility for Rare Isotope Beams FRIB to validate the quality assurance of SRF cavities meanwhile optimizing processing procedures for mass production. Experiments are conducted to correlate surface cleanliness for niobium surfaces with high pressure rinse time using β=0.085 quarter-wave resonators (QWR) cavities. Diagnostic devices; liquid particle counter, surface particle detector and TOC analyzer are used to monitor key parameters for quality control. Rinse water samples are collected during high pressure rinsing to measure liquid particle counts. The SLS 1200 Sampler is used to detect the presence of liquid particles of 0.2 microns and up to 1 micron to set standards for acceptable cleaning thresholds and optimize high pressure rinse time. The QIII+ surface particle detector is used to scan high electric field region for the β=0.085 QWR to ensure high pressure rinsing efficiency. The β=0.085 QWR RF testing data are analyzed and results are presented to demonstrate the correlation between attained acceleration gradients and surface cleanliness.
 
 
MOPB071 Process Developments for Superconducting RF Low Beta Resonators for the ReA3 LINAC and Facility for Rare Isotope Beams 342
 
  • L. Popielarski, C. Compton, L.J. Dubbs, K. Elliott, A. Facco, L.L. Harle, I.M. Malloch, R. Oweiss, J.P. Ozelis, J. Popielarski, K. Saito
    FRIB, East Lansing, USA
 
  Funding: This material is based upon work supported by the U.S. Department of Energy Office of Science under Cooperative Agreement DE SC0000661.
The Facility for Rare Isotope Beams (FRIB) will utilize over 330 superconducting radio frequency (SRF) low beta cavities for its heavy ion driver linac. The SRF department will process and test all cavities prior to string assembly in the cleanroom. The baseline cavity surface and bulk niobium processing procedures have been established. The methods are being optimized for production process rate benchmarking. Additional processes are being developed to increase flexibility and reduce technical risks. This paper will describe procedure developments and experimental results. Topics include high temperature heat treatment for hydrogen degassing, selective chemical etching for cavity frequency tuning, low-temperature bake out and process quality control.
 
 
MOPB090 FRIB Technology Demonstration Cryomodule Test 386
 
  • J. Popielarski, E.C. Bernard, S. Bricker, S. Chouhan, C. Compton, A. Facco, A. Fila, L.L. Harle, M. Hodek, L. Hodges, S. Jones, M. Leitner, D. R. Miller, S.J. Miller, D. Morris, R. Oweiss, J.P. Ozelis, L. Popielarski, K. Saito, N.R. Usher, J. Weisend, Y. Zhang, S. Zhao, Z. Zheng
    FRIB, East Lansing, Michigan, USA
  • M. Klaus
    Technische Universität Dresden, Dresden, Germany
 
  A Technology Demonstration Cryomodule (TDCM) has been developed for a systems test of technology being developed for FRIB. The TDCM consists of two half wave resonators (HWRs) which have been designed for an optimum velocity of β=v/c=0.53 and a resonant frequency of 322 MHz. The resonators operate at 2 K. A superconducting 9 T solenoid is placed in close proximity to one of the installed HWRs. The 9 T solenoid operates at 4 K. A complete systems test of the cavities, magnets, and all ancillary components is presented in this paper.
This material is based upon work supported by the U.S. Department of Energy Office of Science under Cooperative Agreement DE SC0000661.
 
 
TU1A04 FRIB Accelerator Status and Challenges 417
 
  • J. Wei, E.C. Bernard, N.K. Bultman, F. Casagrande, S. Chouhan, C. Compton, K.D. Davidson, A. Facco, P.E. Gibson, T . Glasmacher, K. Holland, M.J. Johnson, S. Jones, D. Leitner, M. Leitner, G. Machicoane, F. Marti, D. Morris, J.P. Ozelis, S. Peng, J. Popielarski, L. Popielarski, E. Pozdeyev, T. Russo, K. Saito, R.C. Webber, M. Williams, Y. Yamazaki, A. Zeller, Y. Zhang, Q. Zhao
    FRIB, East Lansing, USA
  • D. Arenius, V. Ganni
    JLAB, Newport News, Virginia, USA
  • J.A. Nolen
    ANL, Argonne, USA
 
  Funding: This material is based upon work supported by the U.S. Department of Energy Office of Science under Cooperative Agreement DE-SC0000661
The Facility for Rare Isotope Beams (FRIB) at MSU includes a driver linac that can accelerate all stable isotopes to energies beyond 200 MeV/u at beam powers up to 400 kW. The linac consists of 330 superconducting quarter- and half-wave resonators operating at 2 K temperature. Physical challenges include acceleration of multiple charge states of beams to meet beam-on-target requirements, efficient production and acceleration of intense heavy-ion beams from low to intermediate energies, accommodation of multiple charge stripping scenarios (liquid lithium, helium gas, and carbon foil) and ion species, designs for both baseline in-flight fragmentation and ISOL upgrade options, and design considerations of machine availability, tunability, reliability, maintainability, and upgradability. We report on the FRIB accelerator design and developments with emphasis on technical challenges and progress.
 
slides icon Slides TU1A04 [4.531 MB]  
 
TUPB040 Status of the Linac SRF Acquisition for FRIB 564
 
  • M. Leitner, E.C. Bernard, J. Binkowski, B. Bird, S. Bricker, S. Chouhan, C. Compton, K. Elliott, B. Enkhbat, A.D. Fox, L.L. Harle, M. Hodek, M.J. Johnson, I.M. Malloch, D. R. Miller, S.J. Miller, T. Nellis, D. Norton, R. Oweiss, J.P. Ozelis, J. Popielarski, L. Popielarski, K. Saito, M. Shuptar, G.J. Velianoff, J. Wei, M. Williams, K. Witgen, Y. Xu, Y. Yamazaki, Y. Zhang
    FRIB, East Lansing, USA
  • A. Facco
    INFN/LNL, Legnaro (PD), Italy
 
  Funding: This material is based upon work supported by the U.S. Department of Energy Office of Science under Cooperative Agreement DE SC0000661.
The Facility for Rare Isotope Beams (FRIB) will utilize a high-intensity, superconducting heavy-ion driver linac to provide stable ion beams from protons to uranium up to energies of >200 MeV/u and at a beam power of up to 400 kW. The ions are accelerated to about 0.5 MeV/u using a room-temperature 80.5 MHz RFQ and injected into a superconducting cw linac consisting of 330 individual low-beta cavities in 49 cryomodules operating at 2 K. This paper discusses the current status of the linac SRF acquisition strategy as the project phases into construction mode.