Paper |
Title |
Page |
MOP068 |
Beam-Loss Measurement and Simulation of Low-Energy SNS Linac
|
202 |
|
- S. Assadi
ORNL, Oak Ridge, Tennessee
- A. P. Zhukov
RAS/INR, Moscow
|
|
|
We have installed a number of Neutron detectors from the MEBT to the end of CCL [186 MeV]. These detectors are made in collaboration with INR. In this paper we present our implementation and simulation of the losses by inserting Faraday Cups at different energies. We also calibrated neutron detectors and their high voltage dependence. The measured losses are simulated by 3-D transport codes during SCL commissioning. We also discuss future improvements such as interpreting the loss signal in terms of beam current lost in warm part of SNS linac with accurate longitudinal loss distribution as well as plan to automate voltage dependence of the neutron detectors. We compare two different sets of Beam Loss Monitors: Ionization Chambers (detecting X-ray and gamma radiation) and Photo-Multiplier Tubes with a neutron converter (detecting neutrons). We outline such combination is better way to deal with the beam losses than relying on detectors of one type.
|
|