TUP017 A Damper System for the Electron Cooling Beam in the Recycler 283
 
  • P. Varghese, B. Chase, P. W. Joireman
    Fermilab, Batavia, Illinois
 
  The antiproton stacking rate in the Fermilab Recycler has been dramatically improved with the commissioning of the Electron Cooling system last year. Various disturbance sources such as mechanical vibrations in the Pelletron , power line fluctuations and coupling from beam ramps in the nearby Main Injector have added noise components in the electron beam position in the 0.5 to 200 Hz range. An AC coupled damping feedback loop with corrector coils for horizontal and vertical position correction at two upstream points from the BPMs was added to the existing BPM system . The system provides 10 – 20 dB damping in the frequency range above without interfering with other DC beam positioning control loops.