Paper | Title | Page |
---|---|---|
MOP046 | Commissioning of the 7-MeV/u, 217-MHz Injector Linac for the Heavy Ion Cancer Therapy Facility at the University Clinics in Heidelberg | 148 |
|
||
A clinical synchrotron facility designed by GSI for cancer therapy using energetic proton and ion beams (C, He and O) is under construction at the university clinics in Heidelberg, Germany. In this contribution the current status of the injector linac is reported. The installation and commissioning of the linac is performed gradually in three steps for the ion sources and the LEBT, the 400 keV/u RFQ and the 7 MeV/u IH-type drift tube linac. Two powerful 14.5 GHz permanent magnet ECR ion sources from PANTECHNIK as well as the LEBT and the linac RF system have been installed in Heidelberg between November 2005 and March 2006. A test bench with versatile beam diagnostics elements has been designed and installed for the commissioning phase. In April 2006 the two ion sources produced the first ion beams on the site. Extensive RFQ tests using proton beams have been performed at test benches at the IAP and at GSI already during 2004-2006. The 1.4 MW 217 MHz amplifier for the IH tank has also been commissioned at a test setup at GSI in advance to the installation in Heidelberg. The RF tuning of the 20 MV IH-DTL cavity is performed by the IAP in close cooperation with GSI. |