Paper |
Title |
Page |
MOP051 |
Development of an Intense Neutron Source FRANZ in Frankfurt
|
159 |
|
- O. Meusel, L. P. Chau, I. Mueller, U. Ratzinger, A. Schempp, K. Volk, C. Zhang
IAP, Frankfurt-am-Main
- S. Minaev
ITEP, Moscow
|
|
|
The Stern-Gerlach-Center recently founded at the University of Frankfurt gives the possibility for experiments in accelerator physic, astrophysic and material sience research. It is planned to develop an intense neutron generator within the next 4 years. The proton driver linac consists of a high voltage terminal already under construction to provide primary proton beam energies of max. 150 keV. A volume type ion source will deliver a DC beam current of 100-250 mA at a proton fraction of 90%. A low energy beam transport using two solenoids will inject the proton beam into an RFQ while a chopper at the entrance of the RFQ will create a pulse length of 50 ns and a repetition rate up to 250 kHz. A drift tube cavity for the variation of the beam energy in a range of 1.9 2.4 MeV will be installed downstream of the RFQ. Finally a bunch compressor of the Mobley type forms a proton pulse length of 1 ns at the Li target. The maximum energies of the neutrons being adjustable between 100 keV and 500 keV by the primary proton beam. The detailed concept of the high current injector, numerical simulation of beam transport and losses will be presented together with first experimental results.
|
|
MOP046 |
Commissioning of the 7-MeV/u, 217-MHz Injector Linac for the Heavy Ion Cancer Therapy Facility at the University Clinics in Heidelberg
|
148 |
|
- B. Schlitt, R. Baer, W. Barth, T. G. Fleck, M. Hoerr, G. Hutter, C. M. Kleffner, M. T. Maier, A. Peters, M. Schwickert, K. Tinschert, W. Vinzenz, H. Vormann, D. Wilms
GSI, Darmstadt
- R. Cee, E. Feldmeier, B. Naas, S. Scheloske, J. Suhm, S. Vollmer, T. Winkelmann
HIT, Heidelberg
- G. Clemente, U. Ratzinger, A. Schempp
IAP, Frankfurt-am-Main
- S. Minaev
ITEP, Moscow
|
|
|
A clinical synchrotron facility designed by GSI for cancer therapy using energetic proton and ion beams (C, He and O) is under construction at the university clinics in Heidelberg, Germany. In this contribution the current status of the injector linac is reported. The installation and commissioning of the linac is performed gradually in three steps for the ion sources and the LEBT, the 400 keV/u RFQ and the 7 MeV/u IH-type drift tube linac. Two powerful 14.5 GHz permanent magnet ECR ion sources from PANTECHNIK as well as the LEBT and the linac RF system have been installed in Heidelberg between November 2005 and March 2006. A test bench with versatile beam diagnostics elements has been designed and installed for the commissioning phase. In April 2006 the two ion sources produced the first ion beams on the site. Extensive RFQ tests using proton beams have been performed at test benches at the IAP and at GSI already during 2004-2006. The 1.4 MW 217 MHz amplifier for the IH tank has also been commissioned at a test setup at GSI in advance to the installation in Heidelberg. The RF tuning of the 20 MV IH-DTL cavity is performed by the IAP in close cooperation with GSI.
|
|