Paper | Title | Page |
---|---|---|
TU3001 | High-Current Proton Beam Investigations at the SILHI-LEBT at CEA/Saclay | 232 |
|
||
For the injection of a high current proton beam into the future proton LINAC at GSI for FAIR the ion source and the low energy beam transport system have to deliver a 100 mA proton beam with an energy of 95 keV within an acceptance of 0.3 mm mrad (normalized, rms) at the entrance of the RFQ. Besides the ion source a 2-solenoid focusing system is foreseen as an injection scheme for the subsequent RFQ. The beam parameters of the SILHI ion source and the 2-solenoid LEBT setup generally meet these requirements. Therefore joint emittance measurements on various beam parameters have been performed at the end of the LEBT system. In the frame work of the design study for the future proton LINAC it was a unique possibility to investigate the injection of a high current proton beam into a low energy beam transport system under the influence of space charge. The measurements reveal that a proton current of 100 mA can be achieved at the end of the LEBT while the emittance (95 %, rms, normalized) is as high as 0.3 to 0.5 mm mrad. |