Paper |
Title |
Page |
THP092 |
Control System for a Limitation of an Integrated Amount of Beam Charges Delivered from the KEKB Injector Linac
|
800 |
|
- T. Suwada, K. Furukawa, E. Kadokura, M. Satoh
KEK, Ibaraki
|
|
|
A new control system is under construction for radiation safety at the KEKB injector linac. The control system restricts the integrated amount of the beam charges delivered from an electron gun in order to keep the radiation safety with high reliability in a daily operation of the linac. The old control system of the radiation safety has been working based on a software control implemented on a UNIX-based workstation. However, this control system is not possible to be implemented for the long-term linac operation with high reliability. The new control system comprises a charge-integration-type analog circuit mounted along with a CPU chip and a data acquisition system based on programmable logic controllers. The fast analog circuit can detect the beam-charge signals delivered from a wall-current monitor, and control the beam-abort trigger pulses pulse-by-pulse. The new hardware-based control system may stabilize the radiation safety control for the long-term linac operation. In this report the design of the new control system is described along with preliminary test results.
|
|