THP009 Performance of RF Reference Distribution System for the J-PARC Linac 583
 
  • T. Kobayashi
    JAEA/J-PARC, Tokai-Mura, Naka-Gun, Ibaraki-Ken
  • S. Anami, S. Michizono, S. Yamaguchi
    KEK, Ibaraki
  • E. Chishiro
    JAEA, Ibaraki-ken
 
  Installation of the J-PARC linac machines (Phase I) has been almost completed and the beam commissioning will be started in December this year. The error of the accelerating field must be within ±1 degree in phase and ±1% in amplitude. Thus, high phase stability is required as an RF reference. Our objective concerning the phase stability of the reference aims at less than ±0.3 degrees. Last year the installation of the RF reference distribution system was completed. The reference signal is optically distributed to all of the low-level RF control systems by using E/O, O/E, Optical Amplifier and Optical Couplers and so on. The performance of this system was evaluated. The phase stability of ±0.06 degrees was obtained.