MOP77 Design Parameters of the Normal Conducting Booster Cavity for the PITZ-2 Test Stand 204
 
  • V.V. Paramonov, N.I. Brusova, A.I. Kvasha, A. Menshov, O.D. Pronin, A.K. Skasyrskaya, A.A. Stepanov
    RAS/INR, Moscow
  • A. Donat, M. Krasilnikov, A. Oppelt, F. Stephan
    DESY Zeuthen, Zeuthen
  • K. Flöttmann
    DESY, Hamburg
 
  The normal conducting booster cavity is intended to increase the electron bunch energy in the Photo Injector Test (DESY, Zeuthen) stage 2 experiments. The normal conducting cavity is selected due to infrastructure particularities. The L-band cavity is designed to provide the accelerating gradient up to 14 MV/m with the total input RF power 8.6 MW, RF pulse length up to 900 mks and repetition rate 5 Hz. The multi-cell cavity is based on the CDS compensated accelerating structure with the improved coupling coefficient value. The main design ideas and decisions are described briefly together with cavity parameters - RF properties, cooling and pumping circuits.