A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Minaev, S.

Paper Title Page
MOP10 The IH Cavity for HITRAP 54
 
  • C. A. Kitegi, U. Ratzinger
    IAP, Frankfurt-am-Main
  • S. Minaev
    ITEP, Moscow
 
  RFQs are already successfully used to decelerate ions and to match them to ion traps. Within the Heavy Ions TRAP project HITRAP at GSI a combination of an IH drift tube cavity operating at the H11(0) mode and a 4-rod RFQ is proposed to decelerate the 1 ms long heavy ion bunches (up to U92+) from 4 A×MeV to 6 A keV after storage ring extraction. The transition energy from the IH into the RFQ is 0.5AmeV. The operating frequency is 108.408 MHz. The A/q range of the linac is up to 3.A 4-gap quarter wave resonator working at 108.408MHz provides theμbunch structure for the IH. The transmission mainly defined by the buncher is about 30%. An alternative 2nd harmonic bunching section, which allows higher transmission and/or smaller longitudinal emittance, will be discussed.By applying the KONUS dynamics, the 2.7 meter long IH cavity will perform a high efficient deceleration by up 10.5 MV with 200kW rf power. The beam dynamics performed with the LORASR simulation code will be shown. It is aimed to reach an effective shunt impedance around 220MW/m for the IH cavity  
MOP11 The Compact 20 MV IH-DTL for the Heidelberg Cancer Therapy Facility 57
 
  • Y.R. Lu, Y.R. Lu, B. Schlitt
    GSI, Darmstadt
  • S. Minaev
    ITEP, Moscow
  • U. Ratzinger, R. Tiede
    IAP, Frankfurt-am-Main
 
  A clinical synchrotron facility for cancer therapy using energetic proton and ion beams (C, He and O) is under construction and will be installed at the Radiologische Universitätsklinik in Heidelberg, Germany, starting in 2005. The different rf tuning concepts and tuning results for an 1:2 scaled IH-DTL model cavity are presented. Microwave Studio simulations have been carried out for the model and for the real power cavity. Results from the model measurements and the field simulations agree very well also for the higher order modes. The beam matching from the RFQ to the IH-DTL was optimised. Beam dynamics simulations using the LORASR code and starting with a particle distribution at the RFQ exit as calculated with PARMTEQ are presented. The IH drift tube array was matched with the gap voltage distribution resulting from rf model measurements.  
MOP12 KONUS Beam Dynamics Design of a 70 mA, 70 MeV Proton CH-DTL for GSI-SIS12 60
 
  • R. Tiede, G. Clemente, H. Podlech, U. Ratzinger
    IAP, Frankfurt-am-Main
  • W. Barth, L. Groening
    GSI, Darmstadt
  • Z. Li
    IMP, Lanzhou
  • S. Minaev
    ITEP, Moscow
 
  The future scientific program at GSI needs a dedicated proton injector into the synchrotron SIS, in order to increase the proton intensity of the existing UNILAC/SIS12 combination by a factor of 70, resulting in 7· 1012 protons in the synchrotron. A compact and efficient 352 MHz RFQ - CH-DTL combination based on novel structure developments for RFQ and DTL was worked out. For DTLs operated in an H-mode like CH-cavities (H210-mode), the shunt impedance is optimized by use of the KONUS beam dynamics. Beam dynamics simulation results of the CH-DTL section, covering the energy range from 3 to 70 MeV, with emphasis on the low energy front end are presented. Optimization aims are the reduction of emittance growth, of beam losses and of capital costs, by making use of the high acceleration gradients and shunt impedance values provided by the Crossbar H-Type (CH) structure. In addition, the beam dynamics design of the overall DTL layout has to be matched to the power limits of the available 352 MHz power klystrons. The aim is to power each cavity by one klystron with a peak rf power of around 1 MW.