A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Lagniel, J.M.

Paper Title Page
TUP59 Extraction of High Charge Electron Bunch from the ELSA RF Injector - Comparison Between Simulation and Experiment 402
 
  • J. Lemaire, P. Balleyguier, A. Binet, J.M. Lagniel, V. Le Flanchec, N. Pichoff
    CEA/DAM, Bruyères-le-Châtel
  • R. Bailly-Salins, M. Millerioux, Chr. Quine
    CEA/DIF/DPTA/SP2A, Bruyeres-le-Chatel
 
  A new scheme based on a photoinjector and a RF linear accelerator operating at 352 MHz has been recently proposed as a versatile radiographic facility. Beam pulses of 60 ns duration contain 20 succesive electron bunches which will be extracted at 2.5 MeV from a photoinjector then accelerated through the next structure to the final energy of 51 MeV. Bunches carrying 100 nC are required for this purpose. As a first demonstrating step, 50 nC electron bunches have been produced and accelerated to 2.5 MeV with the 144 MHz ELSA photoinjector at Bruyères le Chatel. For this experiment, we compare the results and the numerical simulations made with PARMELA, MAGIC and MAFIA codes.